Canon iR Advance 400iF/ 500iF The toner bottle set lever cannot be operated

User avatar
Expert
Posts: 7
Joined: Sat Oct 21, 2017 9:35 pm

Canon iR Advance 400iF/ 500iF The toner bottle set lever cannot be operated

Postby Expert » Sat Oct 28, 2017 12:15 pm

Models list: Canon imageRUNNER ADVANCE 500iF, 500i, 400i, 400iF
The toner bottle set lever cannot be operated or is hard to operate

Location
Toner bottle set lever

Cause
• When sealing force of the Toner Bottle Cap is large although it is within the specified range, the lever operation force to open/close the cap can be large.
• The toner bottle has not been fully pushed into the rear to hear a sound.
Condition
• When opening a new toner bottle cap that has large sealing force although it is within the specified range
• When repeatedly setting a bottle that contains toner in an undesirable manner

Field Remedy
• Once the toner bottle set lever rotates by approximately 45 degrees, pulling the toner bottle while rotating the set-on lever can easily set the toner bottle.
• Operate the lever after the toner bottle is securely pushed into the rear.

Return to “Canon imageRUNNER ADVANCE 500/400”