  • Code: 389.609
  • Description: RC Sample Block Fail-B-#2-Out. During the B (rough adjustment pattern) patch detection, the #2 (Magenta) patch at the MOB Sensor Out side did not satisfy the defined number of valid sample blocks. (This is a hidden failure. The Color Regi Spec cannot be guaranteed and Data is only recorded in history.)
  • Remedy: Check the density of M color. Is the density of M color normal? Y↓ N→Adjust to correct the density of M color. Check the connection between the MOB Sensor In P/J151 and the MCU PWB P/J415 for connector disconnection, open circuit, short circuit, and poor contact. Is the connection normal? Y↓ N→Connect the MOB Sensor Out P/J151 to the MCU PWB P/J415 properly. Check the M Magnet Roll for contamination, scratches, and distortion. Is the Magnet Roll normal? Y↓ N→Replace the Developer (M) (PL 5.2 Item 8). Check the Transfer Belt for contamination, scratches, and distortion. Is the Transfer Belt normal? Y↓ N→Replace the IBT Assembly. Check the M Imaging Unit for contamination, scratches, and distortion. Is the Imaging Unit normal? Y↓ N→Replace the Imaging Unit (M) Replace the MOB ADC Assembly. If the problem persists, replace the MCU PWB.
  • Code: 389.610
  • Description: RC Sample Block Fail-B-#3-In. During the B (rough adjustment pattern) patch detection, the #3 (Cyan) patch at the MOB Sensor In side did not satisfy the defined number of valid sample blocks. (This is a hidden failure. The Color Regi Spec cannot be guaranteed and Data is only recorded in history.)
  • Remedy: Check the density of C color. Is the density of C color normal? Y↓ N→Adjust to correct the density of C color. Check the connection between the MOB Sensor In P/J150 and the MCU PWB P/J415 for connector disconnection, open circuit, short circuit, and poor contact. Is the connection normal? Y↓ N→Connect the MOB Sensor In P/J150 to the MCU PWB P/J415 properly. Check the C Magnet Roll for contamination, scratches, and distortion. Is the Magnet Roll normal? Y↓ N→Replace the Developer (C) (PL 5.2 Item 7). Check the Transfer Belt for contamination, scratches, and distortion. Is the Transfer Belt normal? Y↓ N→Replace the IBT Assembly Check the C Imaging Unit for contamination, scratches, and distortion. Is the Imaging Unit normal? Y↓ N→Replace Imaging Unit (C). Replace the MOB ADC Assembly. If the problem persists, replace the MCU PWB.
  • Code: 389.612
  • Description: RC Sample Block Fail-B-#3-Out. During the B (rough adjustment pattern) patch detection, the #3 (Cyan) patch at the MOB Sensor Out side did not satisfy the defined number of valid sample blocks. (This is a hidden failure. The Color Regi Spec cannot be guaranteed and Data is only recorded in history.)
  • Remedy: Check the density of C color. Is the density of C color normal? Y↓ N→Adjust to correct the density of C color. Check the connection between the MOB Sensor Out P/J151 and the MCU PWB P/J415 for connector disconnection, open circuit, short circuit, and poor contact. Is the connection normal? Y↓ N→Connect the MOB Sensor Out P/J151 to the MCU PWB P/J415 properly. Check the C Magnet Roll for contamination, scratches, and distortion. Is the Magnet Roll normal? Y↓ N→Replace the Developer (C) (PL 5.2 Item 7). Check the Transfer Belt for contamination, scratches, and distortion. Is the Transfer Belt normal? Y↓ N→Replace the IBT Assembly. Check the C Imaging Unit for contamination, scratches, and distortion. Is the Imaging Unit normal? Y↓ N→Replace Imaging Unit (C). Replace the MOB ADC Assembly. If the problem persists, replace the MCU PWB.
  • Code: 389.613
  • Description: RC Sample Block Fail-B-#4-In. During the B (rough adjustment pattern) patch detection, the #4 (Black) patch at the MOB Sensor In side did not satisfy the defined number of valid sample blocks. (This is a hidden failure. The Color Regi Spec cannot be guaranteed and Data is only recorded in history.)
  • Remedy: Check the density of K color. Is the density of K color normal? Y↓ N→Adjust to correct the density of K color. Check the connection between the MOB Sensor In P/J150 and the MCU PWB P/J415 for connector disconnection, open circuit, short circuit, and poor contact. Is the connection normal? Y↓ N→Connect the MOB Sensor In P/J150 to the MCU PWB P/J415 properly. Check the K Magnet Roll for contamination, scratches, and distortion. Is the Magnet Roll normal? Y↓ N→Replace the Developer (K) (PL 5.2 Item 6). Check the Transfer Belt for contamination, scratches, and distortion. Is the Transfer Belt normal?Y N Replace the IBT Assembly. Check the K Imaging Unit for contamination, scratches, and distortion. Is the Imaging Unit normal? Y↓ N→Replace the Imaging Unit (K) Replace the MOB ADC Assembly. If the problem persists, replace the MCU PWB.
  • Code: 389.615
  • Description: RC Sample Block Fail-B-#4-Out. During the B (rough adjustment pattern) patch detection, the #4 (Black) patch at the MOB Sensor Out side did not satisfy the defined number of valid sample blocks. (This is a hidden failure. The Color Regi Spec cannot be guaranteed and Data is only recorded in history.)
  • Remedy: Check the density of K color. Is the density of K color normal? Y↓ N→Adjust to correct the density of K color. Check the connection between the MOB Sensor Out P/J151 and the MCU PWB P/J415 for connector disconnection, open circuit, short circuit, and poor contact. Is the connection normal? Y↓ N→Connect the MOB Sensor Out P/J151 to the MCU PWB P/J415 properly. Check the K Magnet Roll for contamination, scratches, and distortion. Is the Magnet Roll normal? Y↓ N→Replace the Developer (K) (PL 5.2 Item 6). Check the Transfer Belt for contamination, scratches, and distortion. Is the Transfer Belt normal? Y↓ N→Replace the IBT Assembly(PL 6.1) Check the K Imaging Unit for contamination, scratches, and distortion. Is the Imaging Unit normal? Y↓ N→Replace the Imaging Unit (K). Replace the MOB ADC Assembly. If the problem persists, replace the MCU PWB.
  • Code: 389.616
  • Description: RC Data Over Flow Fail. The correction setting value of calculation result has exceeded the settable range. (This is a hidden failure. The Color Regi Spec cannot be guaranteed and Data is only recorded in history.)
  • Remedy: Is the item that has reached the adjustment range (MIN or MAX), "Fast Scan Margin" or "Slow Scan Margin"? Y↓ N→Check the following: • Check that the value of dc131 NVM Read/Write [760-024] is "0". • The Imaging Unit (Y, M, C, K) for improper installation. If no problems are found, replace the following parts in sequence: • Imaging Unit (Y, M, C, K) • LPH Unit (Y, M, C, K) • Rear Holder Assembly Is the item that has reached the adjustment range (MIN or MAX) "Slow Scan Margin"? Y↓ N→Raise/lower the LPH (Y, M, C, K) 2 to 3 times to check the LPH lift up/down mechanism. If the problem persists, replace the LPH Unit (Y, M, C, K). Replace the MCU PWB.