  • Code: 04
  • Description: Engine Board Malfunction
  • Causes: PWB-A (Engine Control Board)
  • Remedy: 1 Check the PWB-A connector for proper connection and correct as necessary. 2 Change PWB-A.
  • Code: 05
  • Description: Flash ROM Malfunction
  • Causes: PWB-A (Engine Control Board)
  • Remedy: 1 Check the PWB-A connector for proper connection and correct as necessary. 2 Change PWB-A.
  • Code: 08
  • Description: Main Motor Malfunction
  • Causes: Main Motor (M1) PWB-A (Engine Control Board) Power Unit (PU)
  • Remedy: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 M1 operation check. PWB-A PJ8A-5 (REM) PWB-A PJ8A-8 (LOCK) 2-G¡«H 5 Change PWB-A. 6 Change PU (LVPS).
  • Code: 0B
  • Description: Transfer Fan Malfunction
  • Causes: Ventilation Fan Motor (M6) PWB-A (Engine Control Board) Power Unit (PU)
  • Remedy: 1 Check the M6 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 M6 operation check. PWB-A PJ10A-1 (REM) PWB-A PJ10A-3 (LOCK) 2-H 5 Change PWB-A. 6 Change PU.
  • Code: 0C
  • Description: Power Supply Cooling Fan Malfunction
  • Causes: Power Supply Cooling Fan Motor (M4) PWB-A (Engine Control Board) Power Unit (PU)
  • Remedy: 1 Check the M4 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 M4 operation check. PWB-A PJ4A-1 (REM) PWB-A PJ4A-3 (LOCK) 7-I 5 Change PWB-A. 6 Change PU.
  • Code: 10
  • Description: Polygon Motor (Laser) Malfunction
  • Causes: Laser Unit (PH) Unit PWB-A (Engine Control Board)
  • Remedy: 1 Check the cables and connectors for proper connection and correct as necessary. 2 Change Laser Unit (PH) Unit. 3 Change PWB-A.