  • Code: C1A0
  • Description: LCF end fence motor abnormality
  • Causes: LCF end fence motor LCF board PFU board LCF end fence home position sensor LCF end fence stop position sensor
  • Remedy: 1 Is the LCF end fence motor working? (Perform the output check: FS-03- 207) Yes 2 No • Check if the connector of the LCF end fence motor is disconnected. (CN5, CN51) • Check if any of the connectors CN100 and CN101 on the LCF board is disconnected. • Check if the connector CN923 on the PFU board is disconnected. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the LCF board and PFU board are short circuited or open circuited. 2 Are the LCF end fence home/stop position sensors working? (Perform the input check: FS-03-[F1]ON/[8]/[H], FS- 03-[F1]ON/[8]/[G]) Yes 3 No • Check if the connectors of the sensors are disconnected. (CN4, CN40, CN400, CN402, CN403) • Check if either of the connectors CN100 or CN107 on the LCF board is disconnected. • Check if the connector CN923 on the PFU board is disconnected. • Check if the slit reaches the sensors. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the LCF board and PFU board are short circuited or open circuited. 3 PFU board • Check if the conductor pattern on the PFU board is short circuited or open circuited.
  • Code: C1B0
  • Description: LCF transport motor abnormality. The LCF transport motor is not rotating normally (when paper can be fed from any drawer except the LCF).
  • Causes: LCF transport motor LCF board PFU board
  • Remedy: 1 Is the LCF transport motor working? (Perform the output check: FS-03-122/ 172) Yes 2 No • Check if the connector CN3, CN30 of the LCF transport motor is disconnected. • Check if the signal line connector CN100 on the LCF board is disconnected. • Check if the power line connector CN101 on the LCF board is disconnected. • Check if the connector CN923 on the PFU board is disconnected. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the connector pins are disconnected or the harnesses are open circuited. 2 LCF transport motor PFU board • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the LCF transport motor board, LCF board and PFU board are short circuited or open circuited. • Check if the PLL lock signal CN102-3 pin output from the LCF board is always “L” level. • Check if the voltage supplied to the microcomputer input terminal IC4 - 59pin of PFU board is always “L” level.
  • Code: C260
  • Description: Peak detection error
  • Causes: Lens unit SYS board LED Supply harness
  • Remedy: 1 Does the exposure lamp lit? (Perform the output check: FS-03-267) Yes It is lit. 2 No It is not lit. 3 2 Shading correction plate Check if there is any scratch or stain on the shading correction plate. Mirror Check if the mirror is tilted. 1. Check that the lens is reflected in the mirror looking at carriage-1 from the upper position. 2. Check that the mirror is secured at the leaf spring. Carriage 1. Check if the carriage is tilted by moving it to the left stopping point. 2. Check if the wire fixing screw is loosened. 3. Check if the movement of the carriage is unstable due to disengagement of the carriage roller. LED 1. Check if the LED lamp is correctly lit. 2. Check if the harness is connected properly to the LED lamp connector. 3. When the carriage is driven, check if the harness interferes with it or parts are caught in it. CCD board / Lens unit 1. Check if the connector of the CCD board is connected properly. 2. Check if the CCD board is installed properly. (Check that the lens unit is not tilted or the screw is securely tighten.) SYS board 1. Check if the connector of the SYS board (CN120, CN123) is connected properly. 2. Check if the mounted parts on the SYS board are damaged or abnormal. 3. Check if the power is output from the SYS board for CCD. 3 SYS board 1. Check if the supply cable is connected properly to the connector (CN125). 2. Check if the mounted parts on the SYS board are damaged or abnormal. LED 1. Check if the harness of the lamp is connected to the LED light source properly. 2. Check if the lamp is scratched or damaged. 3. Check if the LED harness comes off the board. Supply harness 1. Check if wiring of the supply harness (CN125) is abnormal. 2. Check if the harness is scratched or open circuited.
  • Code: C262
  • Description: Peak detection error (communication error)
  • Causes: Lens unit SYS board Harnesses
  • Remedy: 1 Lens unit 1. Check if the connector is properly connected all the way in the CCD board. (CN001) 2. Check if there is any abnormality in the appearance of parts mounted on the CCD board. 3. Check if +5V is output to the CCD board. 4. Check if +3.3V is output from the CCD board. 5. Replace the Lens unit. 2 SYS board 1. Check if the connector is properly connected all the way in the SYS board. (CN120) 2. Check if there is any abnormality in the appearance of parts mounted on the SYS board. 3. Check if +5V is output to the SYS board. 4. Replace the SYS board. 3 Harnesses 1. Check if the harness has any scratch on it or is open circuited or caught anywhere. 2. Check if there is any abnormality in the connector terminal or the contacting surface of the flat cable. 3. Replace the harness between the SYS board and the CCD board.
  • Code: C270
  • Description: Carriage home position sensor not going OFF within a specified time / Downloading firmware with an incorrect model
  • Causes: CCD board Carriage home position sensor Carriage home position sensor harness SYS board Scan motor Scan motor harness
  • Remedy: 1 Carriage locking Check if the carriage locking screw for packaging is attached. 2 Are the carriages slightly moved to the feeding direction?/Are the carriages staying at a position other than home position? Yes Check if the circuits of the CCD board are abnormal. No 3 3 CCD board ¡E Check if the connector pin is disconnected or the harness is short circuited or open circuited. ¡E Check if the conductor pattern on the CCD board is short circuited or open circuited. ¡E If the model of the firmware downloaded is incorrect, a C270 error (exposure lamp blinks twice) occurs. If the exposure lamp blinks twice, download the correct firmware. 4 Carriage home position sensor 1. Check if the harness of the carriage home position sensor is connected properly. 2. Check if the harness is caught or open circuited. 5 SYS board 1. Check if the connector of the SYS board (CN121, CN124, CN125) is connected properly. 2. Check if the mounted parts on the SYS board are damaged or abnormal. 3. Check if 24 V (CN125) on the SYS board is short circuited. 4. Check if 24 V is supplied to the SYS board (CN125). 6 Scan motor 1. Check if the belt tension is loosened. 2. Check if the motor fixing screw is loosened. 3. Check if the carriage wire and the timing belt come off. 4. Check if the connector (CN124) is connected to the motor properly. 5. Check if the harness of the motor is caught or open circuited. 7 Setting Clear the SRAM data and initialize them. Refer to ƒt P. 9-24 "9.2.5 Precautions and procedure when replacing the SRAM".
  • Code: C280
  • Description: Carriage home position sensor not going ON within a specified time
  • Causes: Carriage home position sensor Carriage home position sensor harness SYS board Scan motor Scan motor harness
  • Remedy: 1 Carriage lock Check if the carriage locking screw for packaging is attached. 2 2 Carriage home position sensor 1. Check if the harness is properly connected to the sensor. 2. Check if the harness is caught or open circuited. 3 3 SYS board 1. Check if the harness (CN121) of the carriage home position sensor is connected properly. 2. Check if the mounted parts on the SYS board are damaged or abnormal. 3. Check if 24 V (CN125) on the SYS board is short circuited. 4. Check if 24 V is supplied to the SYS board (CN125). 4 4 Scan motor • Check if the belt tension is loosened (if the motor screw is loosened). • Check if the wire and the belt come off. • Check if the connector (CN124) is connected to the motor properly. • Check if the harness of the motor is caught or open circuited.