PrintCopy.info service

Toshiba e-Studio 195

Error Codes List page 8

  • Code: E74
  • Description: ADF jam. Stop jam at the reverse sensor: The trailing edge of the original does not pass the reversal sensor after its leading edge has reached this sensor. (RADF)
  • Remedy: 1 Are the read roller and reverse roller stained? Yes Clean the rollers. No 2 2 Is the reverse sensor working? (Perform the input check: 13-[04. SENSOR TEST]) Yes 3 No 1. Check if the connector of the reverse sensor is disconnected. 2. Check if the connector CN4 on the RADF board is disconnected. 3. Check if the connector pins are disconnected or the harnesses are open circuited. 4. Check if the conductor pattern on the RADF board is short circuited or open circuited. 5. Replace the reverse sensor. 6. Replace the RADF board. 3 Replace the RADF board.
  • Code: E86
  • Description: ADF jam. ADF jam access cover open: The ADF jam access cover has opened during ADF operation.
  • Remedy: 1 Is the ADF jam access cover opened? Yes Remove the original, if any, and close the ADF jam access cover. No 2 2 Is the ADF jam access cover switch working? (Perform the input check: 13- [04. SENSOR TEST]) Yes 3 No 1. Check if the connector of the ADF jam access cover switch is disconnected. 2. Check if the connector CN75 on the ADF board is disconnected. 3. Check if the connector pins are disconnected or the harnesses are open circuited. 4. Check if the conductor pattern on the ADF board is short circuited or open circuited. 5. Replace the ADF jam access cover switch. 6. Replace the ADF board. 3 Replace the ADF board.
  • Code: E87
  • Description: ADF jam. ADF open jam: ADF has opened during ADF operation.
  • Remedy: 1 Is the ADF opened? Yes Remove the original, if any, and close the ADF. No 2 2 Is the ADF opening/closing sensor adjusted within the specified range? Yes 3 No Adjust the ADF opening/closing sensor. 3 Is the ADF opening/closing sensor working? (Perform the input check: 13- [04. SENSOR TEST]) Yes 4 No 1. Check if the connector of the ADF opening/closing sensor is disconnected. 2. Check if the connector CN74 on the ADF board is disconnected. 3. Check if the connector pins are disconnected or the harnesses are open circuited. 4. Check if the conductor pattern on the ADF board is short circuited or open circuited. 5. Replace the ADF opening/closing sensor. 6. Replace the ADF board. 4 Replace the ADF board.
  • Code: F14
  • Description: Invalid backup counter: The value of the total counter isinconsistent with that of the backup counter.
  • Remedy: 1 Has the MAIN board been replaced? Yes Download the counter value of the SRAM board to the MAIN board in the setting mode (08-389). No 2 2 Has the SRAM board been replaced? Yes Download the counter value of the MAIN board to the SRAM board in the setting mode (08-388). No 3 3 1. Check if the connector CN2 on the SRAM board and the connector CN2 on the MAIN board are securely connected. 2. Replace the SRAM board. 3. Replace the MAIN board.