  • Code: C26
  • Description: Peak detection error / FPGA configuration error: Lightingof the exposure lamp (white reference) is not detected when power is turned ON.
  • Remedy: 1 Does the exposure lamp light? (Perform the output check in the test mode: 04- 267) Yes Replace the CIS unit. No 1. Check if the connector of the CIS unit are disconnected. 2. Check the MAIN board if the connector (CN6) is disconnected and the harness is short circuited or open circuited. 3. Check if the conductor pattern on the MAIN board is short circuited or open circuited. 4. Replace the MAIN board. 5. Replace the CIS unit.
  • Code: C41
  • Description: Thermistor or heater abnormality at power-ON:Abnormality of service call the thermistor is detected when power is turned ON or the temperature of the fuserroller does not rise in a specified period of time afterpower is turned ON.
  • Remedy: Check Item: Check the thermistors • Check if the connectors are disconnected. • Check if the center, side and edge thermistors are in contact with the surface of the fuser roller properly. • Check if the harnesses of the center, side and edge thermistors are open circuited. Check the heater • Check if the heater is broken. • Check if the connector of the heater is disconnected. • Check if the thermostat is blown. Check the MAIN board • Check if the connectors CN17 are disconnected. • Check if the conductor pattern on the MAIN board is short circuited or open circuited. • Replace the MAIN board. Check the switching regulator • Check if the connectors CN108 are disconnected. Clear the status counter After repairing the matter which caused the error [C41], perform the following: 1. Turn ON the power while [0] and [8] are pressed simultaneously. 2. Key in “400”, then press [ENTER]. 3. Change the current status counter value “1” or “2” to “0”, then press [ENTER] (to cancel [C41]). 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.
    Parts to be replaced: MAIN board Switching regulator
  • Code: C43
  • Description: Thermistor abnormality during warming up or in readystatus after abnormality judgment
  • Remedy: Check Item: Check the thermistors • Check if the connectors are disconnected. • Check if the center, side and edge thermistors are in contact with the surface of the fuser roller properly. • Check if the harnesses of the center, side and edge thermistors are open circuited. Check the heater • Check if the heater is broken. • Check if the connector of the heater is disconnected. • Check if the thermostat is blown. Check the MAIN board • Check if the connectors CN17 are disconnected. • Check if the conductor pattern on the MAIN board is short circuited or open circuited. • Replace the MAIN board. Check the switching regulator • Check if the connectors CN108 are disconnected. Clear the status counter After repairing the matter which caused the error [C43], perform the following: 1. Turn ON the power while [0] and [8] are pressed simultaneously. 2. Key in “400”, then press [ENTER]. 3. Change the current status counter value “4” to “0”, then press [ENTER] (to cancel [C43]). 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.
    Parts to be replaced: MAIN board Switching regulator
  • Code: C44
  • Description: Heater abnormality after abnormality judgment: Thetemperature of the fuser roller has exceeded the range of control (in this case, the main switch turns OFF automatically) or does not even reach the range.
  • Remedy: Check Item: Check the thermistors • Check if the connectors are disconnected. • Check if the center, side and edge thermistors are in contact with the surface of the fuser roller properly. • Check if the harnesses of the center, side and edge thermistors are open circuited. Check the heater • Check if the heater is broken. • Check if the connector of the heater is disconnected. • Check if the thermostat is blown. Check the MAIN board • Check if the connectors CN17 are disconnected. • Check if the conductor pattern on the MAIN board is short circuited or open circuited. • Replace the MAIN board. Check the switching regulator • Check if the connectors CN108 are disconnected. Clear the status counter Change the current status counter value (08-400) “5”, “7” or “9” to “0” for [C44], taking the same procedure as that for [C41]. * The status counter value is as follows in the following cases. Change them to “0” respectively. • The error occurred during warming-up: “5” • The error occurred after the equipment has become ready: “7” • The temperature detected by the center thermistor is 230°C or higher: “9” • The temperature detected by the side thermistor is 230°C or higher: “9” • The temperature detected by the edge thermistor is 230°C or higher: “9” only during printing.
    Parts to be replaced: MAIN board Switching regulator
  • Code: C45
  • Description: Thermistor abnormality during printing: Abnormality of thethermistor is detected during printing.
  • Remedy: Check Item: Check the thermistors • Check if the connector is disconnected. • Check if the edge thermistor is in contact with the surface of the fuser roller properly. • Check if the harness of the edge thermistor is open circuited. Check the MAIN board • Check if the connectors CN17 are disconnected. • Check if the conductor pattern on the MAIN board is short circuited or open circuited. • Replace the MAIN board. Clear the status counter Change the current status counter value (08-400) “6” to “0”.
    Parts to be replaced: MAIN board Switching regulator
  • Code: C55
  • Description: ADF I/F error: Communication error has occurredbetween the ADF and the scanner
  • Remedy: Check the connection. 1. Check if the connector CN71 on the ADF/RADF board is disconnected. 2. Check if the relay connector between the ADF/RADF board and the PFC board is disconnected. 3. Check if the connector CN246 on the PFC board is disconnected. 4. Check if the connector pins are disconnected and the harnesses are open circuited. 5. Check if the conductor patterns on the ADF/RADF board and the MAIN board are short circuited or open circuited. 6. Replace the ADF/RADF board. 7. Replace the MAIN board.
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?
Send message to us