  • Code: A0-18
  • Description: ASIC MAIN firmware inconsistent error
  • Causes: Inconsistency of ASIC firmware version in MFP
  • Remedy: SIM49-1 to execute the firmware version
  • Code: A0-19
  • Description: MFP boot error
  • Causes: ASIC trouble
    Memory trouble
  • Remedy: Extract and insert eMMC PWB
    Replace eMMC PWB
    Replace SCN MFP PWB
  • Code: A0-20
  • Description: MFP firmware and EEPROM data inconsistent error
  • Causes: Inconsistency between MFP firmware version and
    EEPROM data version
  • Remedy: SIM49-1 to execute the firmware version up
  • Code: A0-21
  • Description: PCU firmware and EEPROM data inconsistent error
  • Causes: Inconsistency between PCU firmware version and EEPROM data version
  • Remedy: SIM49-1 to execute the firmware version up
  • Code: A0-22
  • Description: SCN firmware and EEPROM data inconsistent error
  • Causes: Inconsistency between SCN firmware version and EEPROM data version
  • Remedy: SIM49-1 to execute the firmware version up
  • Code: C1-10
  • Description: Main charger error
  • Causes: Open circuit or short circuit of the main charger output
  • Remedy: 1. Use SIM8-2 to check the output of [GB]. If the leakage noise or the flickering on the screen of the panel is detected;
    1) Abnormality of the charger -> Remove and insert the charger or replace the charger.
    2) Imperfect insetion of the charger -> Remove and insert the charger.
    3) Abnormality of MHV Harness (Transformer T101 of the highvoltage PWB) -> Remove and insert MHV harness.
    4) Abnormality of the developing unit -> Insert and remove the developing unit./Replace.
    5) Looseness of screw (upper left of high-voltage PWB , and near the transformer T402) -> Tighten screw again.
    2. Use SIM8-2 to check the output of [GB]. If the leakage noise etc. is not detected;
    1) Charger not inserted. -> Insert the Charger
    2) Disconnection/breakage of MHV harness (Transformer T101 of the high-voltage PWB) -> Insert the harness./Replaces.
    3) High-voltage PWB trouble -> Replace the high-voltage PWB.
    4) PCU PWB trouble -> Replace PCU PWB.
    5) Looseness of screw (upper left of high-voltage PWB , and near the transformer T402) -> Tighten screw again.