Sharp MX2300
Error Codes List page 1
|
|
- Code: A0-01
- Description: PCU ROM abnormality
PCU ROM content trouble
- Causes: Firmware upgrade is not made properly due to power OFF, etc.
- Remedy: Use SIM49-1 to upgrade the firmware.
- Code: A0-02
- Description: SCU ROM abnormality
SCU ROM content trouble
- Causes: Some part of SFU is not upgraded during upgrading of the firmware.
- Remedy: Use SIM49-1 to execute the firmware.
- Code: A0-10
- Description: Controller ROM error
SFU combination error in the controller
- Causes: SFU upgrade was not properly made when upgrading the firmware.
- Remedy: Controller firmware upgrade
- Code: A0-11
- Description: IF version discrepancy (CTL-PCU)
Combination error between CTL and PCU
- Causes: Combination error between CTL and PCU
- Remedy: Check the firmware combination between CTL and PCU.
- Code: A0-12
- Description: IF version discrepancy (CTL-SCU)
Combination error between CTL and SCU
- Causes: Combination error between CTL and SCU
- Remedy: Check the firmware combination between CTL and SCU.
- Code: A0-20
- Description: Machine level error (CTL detection)
Combination error between the machine production/ remodeling and the firmware
- Causes: Combination error between the machine production/ remodeling and the firmware
- Remedy: Check the combination between the machine production/remodeling and the firmware.