  • Code: 0006
  • Description: An error occurs when trying to connect with sub CPU.
  • Causes: A noise on a signal while sending a command. Sub CPU was reset to default. Tried to communicate when Sub CPU was reset to default.
  • Remedy: Check cable connection between Main Board and Servo Board. Check the other cable connections of Servo Board. Servo Board replacement Main Board replacement Flexible cable replacement
  • Code: 0007
  • Description: An error occurs while sending a command.
  • Causes: Servo Board does not work correctly. Sub CPU does not work correctly. There is a bad connection between Main Board and Servo Board. A noise on a signal while sending a command. Sub CPU was reset while sending a command.
  • Remedy: Check cable connection between Main Board and Servo Board. Check the other cable connections of Servo Board. Servo Board replacement Main Board replacement Flexible cable replacement
  • Code: 0008
  • Description: There is a problem with synchronizing serial communication to Sub CPU.
  • Causes: Servo Board does not work correctly. Sub CPU does not work correctly. There is a bad connection between Main Board and Servo Board. A noise on a signal.
  • Remedy: Check cable connection between Main Board and Servo Board. Check the other cable connections of Servo Board. Servo Board replacement Main Board replacement Flexible cable replacement
  • Code: 0008
  • Description: Feed Motor Overcurrent Error 2 (A little load is put on the motor movement for a long time.)
  • Causes: External factors > 1. Media Jamming 2. Carriage is moved by hands. 3. Carriage runs into a thing/hand. 4. Media is stuck because it is caught by the paper pipe. 5. Media is pulled forcedly. 6. Loaded Media is too heavy. < Machine factors > 1. The grease lubrication of the motor gear is not enough. 2. Motor is broken/Life. 3. Servo Board is broken. 4. Carriage fixation to the belt is loose.
  • Remedy:
  • Code: 0009
  • Description: Feed Motor Deviation Error (The order from the CPU does not match the feedback of the Feed Motor.). Feed Motor Overcurrent Error 2 (A little load is put on the motor movement for a long time.)
  • Causes: External factors > 1. Media Jamming 2. Carriage is moved by hands. 3. Carriage runs into a thing/hand. 4. Media is stuck because it is caught by the paper pipe. 5. Media is pulled forcedly. 6. Loaded Media is too heavy. < Machine factors > 1. The grease lubrication of the motor gear is not enough. 2. Motor is broken/Life. 3. Servo Board is broken. 4. Carriage fixation to the belt is loose.
  • Remedy:
  • Code: 0010
  • Description: Network I/F Initialize has not been completed.
  • Causes: Network I/F does not work correctly. Firmware for Network I/F is not installed.