Description: Limit Position Initialize has not been done.
Causes: Limit Position Initialize has not been done.
Remedy: Carry out Limit Position Initialize
Code: 0102
Description: Even though the machine carries out the regular movement, the output of Limit Sensor does not reach the expected value.
Causes: Limit Sensor does not work correctly or is broken.
Remedy: Limit Sensor replacement Check the mechanical backlash or loose with the scanning axes
Code: 0107
Description: Linear Encoder Setup has not been done.
Causes: Linear Encoder Setup has not been done.
Remedy: Carry out Linear Encoder Setup
Code: 0110
Description: Input value from Linear Encoder is not changed when Linear Encoder is setup the origin. When Motor stops during printing, Motor does not complete the movement which is supposed to be done.
Causes: Read error of Linear Encoder. Read error of Encoder on Scan Motor side. Wire is not fixed to Head Carriage firmly.В
Remedy: Confirm whether Encoder Scale is between the slit of Encoder Module in a whole width of the machine Check Cable connection between Linear Encoder Board and Print Carriage Board Confirm connection between Wire and Head Carriage Linear Encoder replacement Scan Motor replacement Main Board replacement
Code: 0120
Description: There is a problem with Thermistor for Pre-Heater F.
Causes: Device has a problem. Thermistor Cable has short circuited or cutline.
Remedy: Check Cable connection around Thermistor Thermistor replacement
Code: 0121
Description: There is a problem with thermistor for Pre-Heater R.
Causes: Device has a problem. Thermistor Cable has short circuited or cutline.
Remedy: Check Cable connection around Thermistor Thermistor replacement