PrintCopy.info service

Roland AJ1000 AdvancedJet

Error Codes List page 7

  • Code: 0175
  • Description: Even though the machine carries out the regular movement, the output of Supply Pump 6 Sensor does not reach the expected value.
  • Causes: Supply Pump 6 Motor has a problem. Supply Pump 6 Sensor has a problem. Supply Pump 6 Magnet has dropped out. Wiring or Flexible Cable has short circuitted or cut-line. Pump Drive Board has a problem. Servo Board has a problem.
  • Remedy: Check Cable connection of Servo Board Check Cable connection of Junction Board Check Supply Pump 6 Magnet Supply Pump 6 Motor replacement Supply Pump 6 Sensor replacement Wiring or Flexible Cable replacement Pump Drive Board replacement Servo Board replacement
  • Code: 0180
  • Description: Even though the machine carries out the regular movement, the output of Maintenance Liquid Pump Sensor does not reach the expected value.
  • Causes: Maintenance Liquid Pump Motor has a problem. Maintenance Liquid Pump Sensor has a problem. Maintenance Liquid Pump Magnet has dropped out. Wiring or Flexible Cable has short circuitted
  • Remedy: Check Cable connection of Servo Board Check Cable connection of Junction Board Maintenance Liquid Pump Motor replacement Maintenance Liquid Pump Sensor replacement Wiring or Flexible Cable replacement Servo Board replacement
  • Code: 0190
  • Description: Thermistor under the BED has a problem.
  • Causes: Device has a problem. Thermistor Cable has short circuited or cutline.
  • Remedy: Thermistor replacement Check Cable connection Heater Board replacement
  • Code: 0200
  • Description: Head 1 is abnormally hot. Head 1 temperature has reached 58°C and above.
  • Causes: Thermistor (Head) has a problem. Flexible Cable has short circuitted or cut-line. Wiring of Head Heater has a problem.
  • Remedy: Check Flexible Cable connection around Head Check Cable connection around Heater Head replacement
  • Code: 0201
  • Description: Head 2 is abnormally hot. Head 2 temperature has reached 58°C and above.
  • Causes: Thermistor (Head) has a problem. Flexible Cable has short circuitted or cut-line.
  • Remedy: Check Flexible Cable connection around Head Head replacement
  • Code: 0202
  • Description: Head 3 is abnormally hot. Head 3 temperature has reached 58°C and above.
  • Causes: Thermistor (Head) has a problem. Flexible Cable has short circuitted or cut-line.
  • Remedy: Check Flexible Cable connection around Head Head replacement
Error Code