  • Code: SC992-00
  • Description: Undefined SC issued.
    An SC, that is not controlled by the system, occurred.
  • Causes: • An SC for the previous model was used mistakenly, etc.
    • Basically a software bug.
  • Remedy: Turn the main power OFF/ON.
  • Code: SC995-01
  • Description: CPM setting error 1
    Comparison of machine serial number (11 digits) and machine identification code.
    Details:
    • Machine serial number cannot be identified because of BICU replacement or malfunctioning.
    • Machine serial number cannot be identified because of NV-RAM replacement
  • Causes: Machine serial number (11 digits) or machine identification code does not match.
  • Remedy: • Enter the machine serial number using SP5-811, and then turn the power on/off.
    • Attach the NV-RAM that was installed previously.
  • Code: SC995-02
  • Description: CPM setting error 2
    Comparison of machine serial number (11 digits) and machine identification code.
    Details: Machine serial number cannot be identified because of NV-RAM replacement or malfunctioning.
  • Causes: Machine serial number (11 digits) or machine identification code does not match.
  • Remedy: • Attach the NV-RAM that was installed previously.
    • Download data on the NV-RAM using SP5-825.
  • Code: SC995-03
  • Description: CPM setting error 3
    Comparison of machine serial number (11 digits) and machine identification code.
    Details: Unable to recognize machine identification code because the controller was replaced incorrectly or is malfunctioning.
  • Causes: Machine serial number (11 digits) or machine identification code does not match.
  • Remedy: Replace it with a specified controller.
  • Code: SC995-04
  • Description: CPM setting error 4
    Comparison of machine serial number (11 digits) and machine identification code.
  • Causes: Machine serial number (11 digits) or machine identification code does not match.
  • Remedy: Return the parts to the original configuration, and then replace them according to the manual.
  • Code: SC997-00
  • Description: Application function selection error
    The application selected by the operation panel key operated abnormally (No response, abnormal ending).
  • Causes: Software bug (mainly the application)
  • Remedy: • Check the optional RAM, DIMM, boards required by the application program.