  • Code: SC332-01 ... SC332-04
  • Description: Toner supply feed lock (01: Bk, 02: C, 03: M, 04: Y)
    Under the condition that the Toner Cartridge has not reached the end, an error that no toner is supplied has been detected over n times in succession. n: The value was set at SP3-131-015.
  • Causes: • Disconnected or broken Toner Supply Solenoid. (Failed to open the toner supply shutter)
    • Disconnection of Toner Supply Clutch
    • Failed PCDU. (Toner leak)
    • Toner clogging
  • Remedy: • Check the connector connection or check for broken wire.
    • Replace the Toner Supply Solenoid
    • Replace the PCDU
    • Replace the Toner Cartridge.
  • Code: SC364-01 ... SC364-04
  • Description: Toner End Sensor output count error (01: Bk, 02: C, 03: M, 04: Y)
    The output count from the Toner End Sensor indicates an average of 0.
  • Causes: - Bad connector contact or connector disconnected/wire broken
    - Failed TE Sensor
    - LED Head mounting error (incorrect calibration of TE Sensor)
  • Remedy: - Turn the main power of the printer OFF and then ON
    - Check the connector connection or check for broken wire.
    - Replace the LED Head.
    - Replace the TE sensor (using the same troubleshooting procedure as for LED).
  • Code: SC365-01 ... SC365-04
  • Description: Toner End Sensor upper limit sensor error (01: Bk, 02: C, 03: M, 04: Y)
    The Toner End Sensor still indicates that the remaining amount of toner is at the "upper limit", although 255 g or more toner has been consumed.
  • Causes: - Stained TE Sensor surface
    - Failed TE Sensor
  • Remedy: • Turn the main power of the printer OFF and then ON.
    • Check the connector connection.
    • Clean/replace the sensor (using the same troubleshooting procedure as for LED).
  • Code: SC370-01
  • Description: TM(ID) Sensor calibration error (Right)*
    The specular light output voltage (Vsg_reg) of the Right TM (ID) Sensor cannot be calibrated to a value in the target range. Upper limit (initially 2.97 V) Lower limit (initially 2.31V)
    * This is the sensor on the left as viewed from the front.
  • Causes: - Disconnected TM(ID) Sensor connector/bad contact
    - Stained TM(ID) Sensor window
    - Failed TM(ID) Sensor
    - Image Transfer Belt loosened or out of place
  • Remedy: • Check the TM(ID) Sensor
    • Clean the TM(ID) Sensor Detection window
    • Check the Image Transfer Belt
    • Replace the TM(ID) Sensor
  • Code: SC370-02
  • Description: TM(ID) Sensor calibration error (Left)*
    The specular light output voltage (Vsg_reg) of the Left TM(ID) Sensor cannot be calibrated to a value in the target range. Upper limit (initially 2.97 V) Lower limit (initially 2.31V)
  • Causes: - Disconnected TM(ID) Sensor connector/bad contact
    - Stained TM(ID) Sensor window
    - Failed TM(ID) Sensor
    - Image Transfer Belt loosened or out of place
  • Remedy: • Check the TM(ID) Sensor
    • Clean the TM(ID) Sensor Detection window
    • Check the Image Transfer Belt
    • Replace the TM(ID) Sensor
  • Code: SC396-01
  • Description: Drum Motor: K Error
    Early Detection • A command to stop the rotation of the motor has been issued right after the power was turned on, but the motor is still rotating.
    Motor Operation Timing • When the motor rotation request or speed change request is issued, the motor is in the stopped state.
    Motor Stop Timing • A command to stop the rotation of the motor has been issued, but the motor is still rotating.
  • Causes: - Disconnected connector
    - Broken signal wire
    - Excessive motor torque
  • Remedy: • Check the connector connection.
    • Turn the power OFF and then ON.
    • Replace the Drum Motor: K.