  • Code: 230
  • Description: FGATE ON error
    The FGATE signal did not assert within 1 second. (The BCU generates the FGATE signal and sends it to the LD unit when the registration sensor switches on.)
  • Causes: Defective GAVD and PCI bridge ASIC. Defective BCU. Defective controller board. Defective harness between BCU and LDB.
  • Remedy: • Turn the Power Switch Off and On. • Connect the harness properly. • Replace the harness. • Replace LD unit. • Replace the controller board.
  • Code: 231
  • Description: FGATE OFF error
    The FGATE signal did not go off within 10 seconds after the machine finished writing. (The BCU generates the FGATE signal and sends it to the LD unit when the registration sensor switches on.)
  • Causes: Defective GAVD and PCI bridge ASIC
  • Remedy: • Turn the Power Switch Off and On. • Replace the controller board.
  • Code: 240
  • Description: LD error
    The IPU detected a problem at the LD unit.
  • Causes: Defective LD unit. Disconnect harness. Disconnect LD Driver.
  • Remedy: • Connect the harness properly. • Replace the LD unit.
  • Code: 312
  • Description: Charge roller current leak
    The PWM duty output exceeded 50% for longer than 200 ms, indicating a leak in the charge roller current.fective BCU.
  • Causes: Cartridge (charge roller) defective. High voltage supply board defective. Disconnect harness.
  • Remedy: • Turn the Power Switch Off and On. • Connect the harness properly. • Replace the AIO unit. • Replace the High voltage power supply board.
  • Code: 320
  • Description: Development Bias leak
    The PWM duty output exceeded 50% for longer than 200 ms, indicating a leak in the charge roller current.
  • Causes: Bias applying section leak. High voltage supply board defective. Disconnect harness. Development Bias CN loose
  • Remedy: • Connect the harnesses properly. • Replace the AIO. • Replace High voltage power supply board.
  • Code: 440
  • Description: Primary Transfer PP output leak
    The PWM duty output exceeded 50% for longer than 200 ms, indicating a leak in the charge roller current.
  • Causes: High voltage supply board defective. Disconnect harness. Development Bias CN loose
  • Remedy: • Connect the harnesses properly. • Replace the AIO. • Replace High voltage power supply board.