PrintCopy.info service

Ricoh MPW3600

Error Codes List page 1

  • Code: 143
  • Description: Scanner Automatic Adjustment Error Automatic adjustment of the CIS failed at power on.
  • Causes: • Standard white strips dirty or not platen plate installed improperly • CIS LED defective and not lighting • CIS-to-PSU harness connector loose, disconnected, or defective • CIS-to-MCU harness connector loose, disconnected, or defective • CIS defective • MCU defective
  • Remedy:
  • Code: 144
  • Description: SIB Communication Error SIB serial transmission did not begin within 1 sec. after power on. No communication with SIB.
  • Causes: • MCU defective • SIB defective • SIB-to-MCU harness connector loose, disconnected, or defective
  • Remedy:
  • Code: 300
  • Description: Charge Corona Output Error After sampling at 10 ms intervals, the chargecorona feedback voltage remained less than 0.5 V for more than 200 ms.
  • Causes: • Charge corona unit defective • High voltage cable defective • Corona wire dirty or defective • CGB power pack fuse, connections loose, broken, or defective • CGB power pack defective
  • Remedy:
  • Code: 305
  • Description: Charge Corona Wire Cleaner Error The charge wire cleaner did not: (1) come from the home position within 5 s, or (2) did return to the home position within 3.75 s due to wire cleaner overload.
  • Causes: • Cleaner unit blocked or damaged • Until replacement parts become available, set SP2804 to "0" to disable the charge-corona cleaning function so the machine can operate.
  • Remedy:
  • Code: 392
  • Description: Development Bias Error The development bias feedback voltage was less than 0.3 V for longer than 200 ms while the PWM duty value was more than 5% (indicating a development bias leak).
  • Causes: • Bias terminal damaged • High voltage cable damaged, defective • CGB power pack defective
  • Remedy:
  • Code: 400
  • Description: ID Sensor Auto Adjustment Error Vsg did not reach 4 ±0.2 V when the ID sensor was initialized with SP3001-2.
  • Causes: • ID sensor dirty • ID sensor harness, connector loose, disconnected, damaged, defective • ID sensor defective • MCU defective • Development unit defective • CGB power pack defective
  • Remedy: