PrintCopy.info service

Ricoh MPC305SPF

  • Code: 396
  • Description: Drum/Development motor error: Bk
    The machine detects a High signal from the drum/development motor for 2 seconds after the drum/development motor turned on.
  • Causes: Overload on the drum/development motor. Defective drum/development motor. Defective harness. Shorted 24 V fuse on the PSU. Defective interlock system.
  • Remedy: 1. Check or replace the harness. 2. Replace the drum/development motor. 3. Replace the 24V fuse on the PSU.