  • Code: 144
  • Description: SBU transmission error
    After the SBU switches on, the BCU detects one of the following conditions on the SBU: • 1 s after power on, the SYDO signal does not go high, even after 1 retry. • 1 s after power on, the SYDO signal goes high, but the SBU ID could not be read after 3 attempts.
  • Causes: • SBU defective • SIOB defective • BCU defective • Harness between the SBU - SIOB is disconnected • Harness between the SIOB - BCU is disconnected • Harness between the SIOB – PSU is disconnected
  • Remedy:
  • Code: 161-001
  • Description: IPU error
    The error result of self-diagnostic by the ASIC on the BICU is detected.
  • Causes: • Defective BICU • Defective connection between BICU and SBU
  • Remedy: 1. Check the connection between BICU and SBU. 2. Replace the BICU.
  • Code: 161-002
  • Description: IPU error
    The machine detects an error during an access to the Ri.
  • Causes: • Defective BICU board
  • Remedy: Replace the BICU board.
  • Code: 161-003
  • Description: IPU error
    The IPU fails to configure or initialize the DRAM.
  • Causes: • Defective BICU board
  • Remedy: Replace the BICU board.
  • Code: 165
  • Description: Copy data security unit error B829
    The copy data security option is installed by not operating correctly.
  • Causes: • Copy data security card corrupted • The board is not installed or the board is defective
  • Remedy:
  • Code: 181
  • Description: Inverter Fan Error
    When the exposure lamp is triggered on, the inverter fan motor does not rotate.
  • Causes: • SIOB defective • BCU defective • Inverter fan motor defective • Harness between the inverter fan motor - SIOB is disconnected • Harness between the SIOB – BCU is disconnected • Harness between the SIOB – PSU is disconnected
  • Remedy: