  • Code: 144
  • Description: SBU connection error
    The SBU connection cannot be detected at power on or recovery from the energy save mode.
  • Causes: • Defective SBU • Defective harness • Defective detection port on the BICU
  • Code: 161
  • Description: IPU error
    The error result of self-diagnostic by the ASIC on the IPU is detected.
  • Causes: • Defective IPU • Defective connection between IPU and SBU
  • Code: 162
  • Description: IPU PCIE Communication error
    The link up interrupt did not proceed from the LYRA when the main switch was turned on or when recovering from the energy saver mode.
  • Causes: Defective IPU
    Defective BCU
  • Code: 165
  • Description: Copy Data Security Unit error
    The copy data security board is not detected when the copy data security function is set "ON" with the initial setting.
    A device check error occurs when the copy data security function is set to "ON" with the initial setting.
  • Causes: • Incorrect installation of the copy data security board • Defective copy data security board
  • Code: 202
  • Description: Polygon motor error 1: ON timeout
    The polygon mirror motor does not reach the targeted operating speed within 10 sec. after turning on or changing speed
  • Causes:
  • Code: 203
  • Description: Polygon motor error 2: OFF timeout
    The polygon mirror motor does not leave the READY status within 3 sec. after the polygon motor switched off.
  • Causes: