PrintCopy.info service

Ricoh MP5001

Error Codes List page 4

  • Code: 230
  • Description: FGATE ON error
    The FGATE signal does not assert within the prescribed time. (The BICU generates the FGATE signal and sends it to the LD unit when the registration sensor switches on.)
  • Causes:
  • Code: 231
  • Description: FGATE OFF error
    The FGATE signal does not assert within the prescribed time. (The BICU generates the FGATE signal and sends it to the LD unit when the registration sensor switches on.)
  • Causes: • BICU defective • BICU, Controller board harness loose or broken • Controller board defective.
  • Code: 240
  • Description: LD errorThe IPU detected a problem at the LD unit.
  • Causes: • Worn-out LD • Disconnected or broken harness of the LD.
  • Code: 26
  • Description: Shift jogger motor 1 error
    The side fence does not retract within the prescribed time after the shift jogger motor 1 switches on. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.
  • Causes: • Shift jogger motor 1 disconnected, defective • Shift jogger motor 1 overloaded due to obstruction • Shift jogger 1 HP sensor disconnected, defective
  • Code: 302
  • Description: Charge roller bias leak
    A charge roller bias leak signal was detected.
  • Causes: • Charge roller damaged • High voltage supply board defective • PCDU harness defective or disconnected
  • Code: 304
  • Description: Charge roller bias correction leak
    The charge roller bias correction is performed twice even if the maximum charge roller bias (-2000V) is applied to the roller.
  • Causes: • ID sensor defective • Worn charge roller • Charge roller damaged
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?
Send message to us