Error Codes List page 6
|
|
- Code: 621
- Description: ADF connection error
An incorrect ADF (an ADF for some other copier) is detected.
- Causes: ADF incorrect (The ADF for B039/B040/B043 or B121/B122/B123 is installed on this machine.)
- Code: 760
- Description: ADF gate abnormal 1
The ADF Gate signal line between the ADF main board and the BICU is disconnected.
- Causes: - ADF main board defective
- Input/output board defective
- Poor connection (ADF Gate line) between the
- ADF main board and the BICU.
- Code: 761
- Description: ADF gate abnormal 2
The FGATE signal is not issued from the ADF within 30 seconds after the ADF starts feeding.
- Causes: - ADF connector defective
- SBU board defective
- Code: 762
- Description: ADF gate abnormal 3
The FGATE signal is not terminated by the ADF within 60 seconds after the ADF starts feeding.
- Causes: - ADF connector defective
- SBU board defective
- Code: 901
- Description: Mechanical total counter
The mechanical total counter does not work properly.
- Causes: - Mechanical total counter defective
- BICU defective
- Disconnected mechanical total counter
- Code: 903
- Description: Engine total counter error
The checksum of the total counter is not correct.
- Causes: - NVRAM on the BICU defective