PrintCopy.info service

Ricoh MP1900

Error Codes List page 6

  • Code: 621
  • Description: ADF connection error
    An incorrect ADF (an ADF for some other copier) is detected.
  • Causes: ADF incorrect (The ADF for B039/B040/B043 or B121/B122/B123 is installed on this machine.)
  • Code: 760
  • Description: ADF gate abnormal 1
    The ADF Gate signal line between the ADF main board and the BICU is disconnected.
  • Causes: - ADF main board defective
    - Input/output board defective
    - Poor connection (ADF Gate line) between the
    - ADF main board and the BICU.
  • Code: 761
  • Description: ADF gate abnormal 2
    The FGATE signal is not issued from the ADF within 30 seconds after the ADF starts feeding.
  • Causes: - ADF connector defective
    - SBU board defective
  • Code: 762
  • Description: ADF gate abnormal 3
    The FGATE signal is not terminated by the ADF within 60 seconds after the ADF starts feeding.
  • Causes: - ADF connector defective
    - SBU board defective
  • Code: 901
  • Description: Mechanical total counter
    The mechanical total counter does not work properly.
  • Causes: - Mechanical total counter defective
    - BICU defective
    - Disconnected mechanical total counter
  • Code: 903
  • Description: Engine total counter error
    The checksum of the total counter is not correct.
  • Causes: - NVRAM on the BICU defective
Error Code