PrintCopy.info service

Ricoh M118 SP3500SF

Error Codes List page 1

  • Code: 202
  • Description: Polygon motor on timeout error
    The polygon mirror motor does not reach the targeted operating speed within 10 sec. after turning.
  • Causes: Polygon motor/driver board harness loose or disconnected. Polygon motor/driver board defective. Laser optics unit defective. 1. Turn the main power off/on the machine. 2. Replace the interface harness of the laser optics unit. 3. Replace the laser optics unit.
  • Code: 203
  • Description: Polygon motor off timeout error
    The polygon mirror motor does not leave the READY status within 20 sec. after the polygon mirror motor switched off.
  • Causes: Polygon motor/driver board harness loose or disconnected. Polygon motor/driver board defective. Laser optics unit defective. 1. Turn the main power off/on the machine. 2. Replace the interface harness of the laser optics unit. 3. Replace the laser optics unit.
  • Code: 204
  • Description: Polygon motor lock signal error
    The signal remains HIGH for 200 ms (or 4times in 50msec polling) while the polygon mirror motor is rotating.
  • Causes: Polygon motor/driver board harness loose or disconnected. Polygon motor/driver board defective. Laser optics unit defective. 1. Turn the main power off/on the machine. 2. Replace the interface harness of the laser optics unit. 3. Replace the laser optics unit.
  • Code: 220
  • Description: Beam Synchronize error
    The laser synchronizing detection signal for LD is not output within 400msec after the LD unit has turned on.
  • Causes: Disconnected cable from the laser synchronizing detection unit or defective connection. Defective laser synchronizing detector. Defective LD. Defective ECB. 1. Check the connectors. 2. Replace the laser optics unit. 3. Replace the ECB.
  • Code: 268
  • Description: Laser Scanning Unit thermistor error
    At power on, the temperature sensor in the optics unit detected a temperature lower than -30°C for more than 4 sec. -or- It detected a temperature higher than 105°C for more than 1sec.
  • Causes: Thermistor disconnected (causes extremely low temperature reading) Thermistor damaged and short circuited (causes extremely high temperature reading) 1. Turn the machine's main power off, and then on. 2. Replace the thermistor.
  • Code: 491
  • Description: Bias leak
    An error signal is detected for 0.2 seconds when changing the development unit.
  • Causes: Defective transfer roller. Defective high voltage power pack. 1. Turn the machine's main power off, and then on.