PrintCopy.info service

Ricoh M0C4 SP330SN

Error Codes List page 2

  • Code: SC520
  • Description: Main motor error
    • The machine does not detect a main motor lock signal within 2 seconds after the main motor started to rotate.
    • The machine does not release a main motor lock signal within 2 seconds after the main motor switched off.
    • The machine detects a main motor lock signal every 100 msec. for seven times consecutively, after the main motor started to rotate stably.
  • Causes: • Torque overload
    • Defective main motor
    • Disconnected or defective motor harness
  • Remedy: 1. Turn the power OFF and ON.
    2. Replace the main motor if the torque load is normal.
    3. Clean/replace the AIO and/or fusing unit if the torque load is abnormal.
    4. Replace the motor harness.
  • Code: SC530
  • Description: Cooling fan error
    The FAN lock signal – High for 10 seconds, after the cooling fan motor started to rotate.
  • Causes: Disconnected or defective fan motor harness
  • Remedy: 1. Turn the power OFF and ON.
    2. Replace the cooling fan.
    3. Replace the fan motor harness.
  • Code: SC541
  • Description: Fusing thermistor error
    The thermistor output is less than 0°C for 5 seconds after the fusing lamp turns ON.
  • Causes: Disconnected or defective fusing thermistor
  • Remedy: 1. Reset the SC.
    2. Replace the fusing unit.
    3. Replace the drawer harness.
    4. Replace the PSU.
  • Code: SC542-01
  • Description: Fuser reload error
    The fusing temperature rises 6°C or less in 1.5 seconds; and this continues 5 times consecutively.
  • Causes: • Defective or deformed thermistor
    • Incorrect power supply input at the main power socket
  • Remedy: 1. Reset the SC.
    2. Replace the fusing unit.
    3. Replace the drawer harness.
    4. Replace the PSU.
  • Code: SC542-02
  • Description: Fuser reload error
    The fusing temperature has not reached 45°C within 9 seconds (after the fusing lamp comes ON while the machine is warming-up).
  • Causes: • Defective or deformed thermistor
    • Incorrect power supply input at the main power socket
  • Remedy: 1. Reset the SC.
    2. Replace the fusing unit.
    3. Replace the drawer harness.
    4. Replace the PSU.
  • Code: SC542-03
  • Description: Fuser reload error
    The fusing unit does not attain reload temperature within a predetermined time after the fusing temperature control starts.
  • Causes: • Defective fusing lamp
    • The overheat protection mechanism started working
  • Remedy: 1. Reset the SC.
    2. Replace the fusing unit.
    3. Replace the drawer harness.
    4. Replace the PSU.