  • Code: 500
  • Description: Main motor lock
    The machine does not detect a main motor lock signal within 1 second after the main motor starts to rotate. -or- The machine does not detect a main motor lock signal for 250 ms continuously while the main motor is rotating.
  • Causes: Mechanical overload on the drive mechanism. Main motor defectivess.
  • Remedy: • Remove foreign materials on the drive mechanism. • Turn the Power Switch Off and On. • Connect the harnesses properly. • Replace the main motor.
  • Code: 530
  • Description: Exhaust fan motor error
    The CPU detects an exhaust fan lock signal for more than 2 seconds.
  • Causes: Mechanical overload on the Exhaust fan mechanism. Exhaust fan harness loose or broken
  • Remedy: • Remove foreign materials on the drive mechanism. • Turn the Power Switch Off and On. • Connect the harnesses properly. • Replace the Exhaust fan.
  • Code: 531
  • Description: Reverse Fan Motor error
    The CPU detects a Reverse fan lock signal for more than 2 seconds.и#0
  • Causes: Mechanical overload on the Reverse fan mechanism. Reverse fan harness loose or broken
  • Remedy: • Remove foreign materials from the reverse fan. • Turn the Power Switch Off and On. • Connect the harnesses properly. • Replace the reverse fan.
  • Code: 532
  • Description: PSU Fan Motor error
    The CPU detects a PSU fan lock signal for more than 2 seconds.
  • Causes: Mechanical overload on the PSU fan mechanism. PSU fan harness loose or broken
  • Remedy: • Remove foreign materials from the PSU fan. • Turn the Power Switch Off and On. • Connect the harnesses properly. • Replace the PSU fan.
  • Code: 533
  • Description: PSU2 Fan Motor error
    The CPU detects a PSU2 fan lock signal for more than 2 seconds
  • Causes: Mechanical overload on the PSU2 fan mechanism. PSU2 fan harness loose or broken
  • Remedy: • Remove foreign materials from the PSU2 fan. • Turn the Power Switch Off and On. • Connect the harnesses properly. • Replace the PSU2 fan.
  • Code: 534
  • Description: AIO Fan Motor error
    The CPU detects an AIO fan lock signal for more than 2 seconds.
  • Causes: Mechanical overload on the AIO fan mechanism. AIO fan harness loose or broken
  • Remedy: • Remove foreign materials from the AIO fan. • Turn the Power Switch Off and On. • Connect the harnesses properly. • Replace the AIO fan.