PrintCopy.info service

Ricoh IMC2000

Error Codes List page 2

  • Code: SC142-00
  • Description: White level detection error
    The white level cannot be adjusted to the second target level within the target during auto gain control.
  • Causes: • Condensation in scanner unit
    • Scanner Carriage defective
    • Harness defective
    • Connector defective (disconnected, loose)
    • White plate dirty or installed incorrectly
  • Remedy: Check if the SC occurs by turning the power OFF then ON. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power after each step.
    1. Reconnect the following connectors: • Scanner Carriage - BICU harness (FFC) • SBU - LEDB harness (FFC)
    2. Check the white reference seal that attached back of sheet-through exposure glass. Replace the sheet-through exposure glass, if dirty or damaged.
    3. Replace the scanner carriage.
    4. Replace the following harnesses: • Scanner Carriage - BICU harness (FFC)
    5. Replace the BICU (PCB10).
  • Code: SC144-00
  • Description: SBU Communication Error
    • The machine cannot detect that the Scanner Carriage is connected.
    • The machine cannot communicate with the Scanner Carriage.
    • The communication data is incorrect.
  • Causes: • Scanner Carriage defective
    • BICU defective
    • Harness defective
  • Remedy: Check if the SC occurs by turning the power OFF then ON. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power after each step.
    1. Reconnect the following connectors: • Scanner Carriage - BICU harness (FFC)
    2. Replace the Scanner Carriage.
    3. Replace the BICU (PCB10).
    4. Replace the following harnesses: • Scanner Carriage - BICU harness (FFC)
  • Code: SC151-00
  • Description: Black Level Error: Side 2
    The black level scanned is not specified range.
  • Causes: • CIS for SPDF defective
    • SPDF main board defective
    • Harness defective
  • Remedy: Check if the SC occurs by turning the power OFF then ON. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power after each step.
    1. Reconnect the SPDF main board - CIS connectors if they are disconnected, or loose.
    2. Replace the CIS for SPDF
    3. Replace the following harnesses: • SPDF main board - CIS • BICU -SPDF main board
    4. Replace the SPDF main board.
  • Code: SC152-00
  • Description: White Level Error: Side 2
    • The shading data peak value read out from the CIS is not specified range from the target value.
  • Causes: • CIS defective
    • White roller defective
    • SPDF main board defective
    • Harness defective
  • Remedy: Check if the SC occurs by turning the power OFF then ON. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power after each step.
    1. Reconnect the SPDF main board - CIS connectors if they are disconnected, or loose.
    2. Replace the CIS for SPDF
    3. Replace the following harnesses: • SPDF main board - CIS • BICU -SPDF main board
    4. Replace the SPDF main board.
  • Code: SC154-00
  • Description: Scanner Communication Error: Side 2
    The value read out from the ASIC and FROM area inside the CIS is different from the expected value.
  • Causes: • CIS defective
    • "FROM" area error
    • SPDF main board defective
    • Connector defective (loose, broken)
  • Remedy: Check if the SC occurs by turning the power OFF then ON. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power after each step.
    1. Reconnect the SPDF main board - CIS connectors if they are disconnected, or loose.
    2. Replace the CIS for SPDF
    3. Replace the following harnesses: • SPDF main board - CIS • BICU -SPDF main board
    4. Replace the SPDF main board.
  • Code: SC161-02
  • Description: IPU (BICU) error (Lsync Error: Side 2)
    The machine detects the error from the results of self-diagnostic test before scanning the side 2.
  • Causes: • harness defective between CIS and BICU (disconnected, loose)
    • CIS defective
    • BICU defective (ASIC: Macaron error)
  • Remedy: Check if the SC occurs by turning the power OFF then ON. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power after each step.
    1. Reconnect the BICU - CIS connectors if they are disconnected, or loose.
    2. Replace the CIS for SPDF.
    3. Replace the BICU - CIS harness.
    4. Replace the BICU (PCB10).