PrintCopy.info service

Ricoh G071 CL5000 U-P1

Error Codes List page 2

  • Code: 280
  • Description: Image transfer belt mark detection error . An imaging process starts. - No belt mark is detected in 1 revolution. . A color imaging process starts. - A mono color image is transferred. - FGATE becomes active. - No belt mark is detected in 1 revolution. . Thick paper or OHP film is used. - The belt slows down. - No belt mark is detected in 1 revolution.
  • Causes: • Defective BCU • Poor electrical connection • Noise
  • Code: 281
  • Description: GAPCI communication error Data is transferred. - The CPU does not detect the communication ACK signal from GAPCI.
  • Causes: • Defective BCU
  • Code: 282
  • Description: GAVD communication error Data is transferred. - The CPU does not detect the communication ACK signal from GAVD.
  • Causes: • Defective BCU
  • Code: 300
  • Description: Charge corona unit electrical leak The charge corona unit keeps outputting; the unit is operating at the minimum PWM duty value. - 4.5 Volt (or more) is returning for 60 milliseconds.
  • Causes: • Short circuit in the charge corona unit • Defective high voltage supply board • Defective harness (BCU - high voltage supply board)
  • Code: 301
  • Description: Charge corona unit disconnection The charge corona unit keeps outputting. - The unit is operating at the maximum PWM duty value for 60 milliseconds.
  • Causes: • Defective PCU installation • Defective high voltage supply board • Defective harness (BCU - high voltage supply board)
  • Code: 302
  • Description: Charge grid electrical leak The charge grid keeps outputting. - The returning voltage exceeds the target by 0.5 Volt or more for 120 milliseconds.
  • Causes: • Short circuit in the charge grid • Defective high voltage supply board • Defective harness (BCU - high voltage supply board)