Description: <D0B2,D0B3> D Total counter error • If the counter values (4 bits) for the machine and mirroring agree, the SUM value of the machine is recalculated, and it does not agree with the SUM value of upper 4 bits, this SC is issued. • If the counter values (4 bits) for the machine and mirroring do not agree, recalculate the SUM values for the machine and mirroring. If the values for both machine and mirroring do not agree with the SUM value of upper 4 bits, this SC is issued.
Causes: EEPROM defective
Remedy: Replace the EEPROM.
Code: 920-02
Description: <D0B4> B Printer error (WORK memory not acquired) When an error is detected in the application, which makes continued operation impossible.
Remedy: • Turn the main power off/on. • Increase the memory storage capacity.
Code: 920-04
Description: <D0B4> B Printer error (Filter process not started) When an error is detected in the application, which makes continued operation impossible.