Description: Scanner Fan Error: Right Side The fan located on the right side of the exposure unit is not rotating.
Causes: • Check the fan connections • Fan defective • Check SBU connection • SBU defective
Remedy:
Code: 185
Description: CIS transmission error Error caused during ASIC register's automatic initialization on the CIS, or during transmission between the CIS – DF.
Causes: • Harness between the CIS – DF is disconnected • CIS defective
Remedy:
Code: 186
Description: CIS LED error LED on the CIS causes error • During initializing, the ration of the average between leading-edge area and rearedge is beyond the permissible level (0.7 – 1.43). • During scanning, the shading data peak is under 32(8bit).
Causes: • Harness CN210 and CN220 on ADF are disconnected. • Otherwise, replace CIS.
Remedy:
Code: 187
Description: CIS BK level error The BK level scanned by CIS is abnormal. The BK level average of R, G or B is/are not from 2 to 62. 0 < Calibrated BK data level < 255(10bit).
Causes: • Turn off the machine. • Make sure CN210 and CN220 are connected firmly. • Turn on the machine.
Remedy:
Code: 188
Description: CIS white level error The shading data peak detected from the CIS is abnormal.
Causes: • CIS defective
Remedy: 1. Make sure CN210 and CN220 are connected firmly. 2. Replace the CIS.
Code: 189
Description: CIS gray balance adjustment error The adjustment error occurs during the test after adjusting the gray balance.
Causes: • CIS defective
Remedy: 1. Retry the gray balance adjustment. 2. If the machine does not recover, do the following steps. • Turn off the machine. • Make sure CN210 and CN220 are connected firmly. • Turn on the machine. 3. If the machine does not recover, replace the CIS.