Ricoh D046 MPW5100 Be-C1

Error Codes List page 1

  • Code: SC101
  • Description: Lamp error Lamp does not light at power on.
  • Causes: If cycling the machine power off/on does not solve the problem: • Clean the white plate • Clean the CIS glass • Lamp regulator connection loose broken, defective • CIS, IPU, BCU connection loose broken defective • Harness connection between Xenon lamp and lamp regulator loose broken defective • Harness between CIS and IPU loose, broken, defective • Harness between CIS and PSU loose, broken, defective • One or more defective: CIS, IPU, BCU, PSU, Xenon lamp
  • Remedy:
  • Code: SC144
  • Description: CIS communication error A serial communication error occurred with the CIS due to a PCB malfunction or loose connection.
  • Causes: If cycling the machine power off/on does not solve the problem: • Harness between CIS and IPU loose broken defective • Harness between CIS and PSU loose, broken, defective • CIS defective • IPU defective • BCU defective
  • Remedy:
  • Code: SC161
  • Description: IPU Error Three attempts to configure the Cetus chip on the IPU board failed when the machine was switched on or when machine recovered from the energy save mode.
  • Causes: • Replace the IPU
  • Remedy:
  • Code: SC180
  • Description: Left scanner fan lock The BCU detected a left scanner fan lock signal 5 sec. after the machine was switched on.
  • Causes: If cycling the machine power off/on does not solve the problem: • Left scanner fan harness connection to the IOB loose, broken, defective • Left scanner fan defective • IOB defective • BCU defective
  • Remedy:
  • Code: SC181
  • Description: Right scanner fan lock The BCU detected a right scanner fan lock signal 5 sec. after the machine was switched on.
  • Causes: If cycling the machine power off/on does not solve the problem: • Left scanner fan harness connection to the IOB loose, broken, defective • Left scanner fan defective • IOB defective • BCU defective
  • Remedy:
  • Code: SC186
  • Description: Gray balance adjustment error
  • Causes: The value for gray balance was detected out of range after gray adjustment.
  • Remedy: If cycling the machine power off/on does not solve the problem: • Clean the white strip • Clean the CIS glass • Check the following harnesses for loose, broken, or defective connectors: 1. Xe lamp to lamp regulator 2. Lamp regulator to CIS 3. CIS to IPU 4. CIS to IPU 5. IPU to IOB • One of the following boards is defective 1. CIS 2. IPU 3. IOB 4. BCU