PrintCopy.info service

Ricoh CL4000HDN

Error Codes List page 1

  • Code: 195
  • Description: Incorrect serial number [D] When checking the registered product number, it does not match the printer.s product number.
  • Causes: • Registered product number does not match the printer.s product number.
  • Remedy: 1. Try again to input the correct product number with SP5811-001.
  • Code: 202
  • Description: Polygon motor error: Time out with the polygon motor activated [D] After the polygon motor turns on or changes the speed, the SCRDY_N is not active within 10 seconds.
  • Causes: • Disconnected cable from the polygon motor drive board or defective connection • Defective polygon motor or drive board
  • Remedy:
  • Code: 203
  • Description: Polygon motor error: Time out with the polygon motor inactivated [D] After the polygon motor turns off or changes the speed, the SCRDY_N is not inactive within 10 seconds.
  • Causes: • Disconnected cable from the polygon motor drive board or defective connection • Defective polygon motor or drive board
  • Remedy:
  • Code: 204
  • Description: Polygon motor error: XSCRDY signal error [D] PMRDY_N signal consecutively detects that the polygon motor is an inactive state while LDB unit scans.
  • Causes: • Disconnected cable from the polygon motor drive board or defective connection • Defective polygon motor or drive board
  • Remedy: 1. Check the connectors. 2. Replace the polygon motor. 3. Replace the polygon motor drive board.
  • Code: 205
  • Description: Polygon motor error: XSCRDY signal not stable [D] PMRDY_N signal consecutively detects that the polygon motor is an inactive state while the polygon motor turns on or changes the speed.
  • Causes: • Disconnected cable from the polygon motor drive board or defective connection • Defective polygon motor or drive board.
  • Remedy: 1. Check the connectors. 2. Replace the polygon motor. 3. Replace the polygon motor drive board.
  • Code: 210
  • Description: Trailing edge laser detection error: [K] [C] The laser synchronizing detection signal for LDB [K] of the trailing edge is not detected for one second after the LDB unit turned on when detecting the main scan magnification.
  • Causes: • Disconnected cable from the laser synchronizing detection unit or defective connection • Defective laser synchronizing detector • Defective LDB • Defective EGB
  • Remedy: 1. Check the connectors. 2. Replace the laser-synchronizing detector. 3. Replace the LDB. 4. Replace the EGB.