PrintCopy.info service

Ricoh Aficio 3260C

Error Codes List page 2

  • Code: SC161
  • Description: IDU error
    After the command is written into the DFID self-diagnosis startup register, the correct value is not stored in the register for the prescribed length of time after power on. -or- After the negate interruption of FGATE occurs, IDU is not recognized within the prescribed time during scanning.
  • Causes: • IPU board defective (defective connection between ASIC and DFID, defective LSYNC)
  • Code: SC180
  • Description: Scanner fan lock
    001 One of the fan motors next to the exposure lamp did not switch on within 0.5 sec after the CPU issued the ON signal. 002 The scanner fan motor next to the SIOB did not switch on within 0.5 sec. after the CPU issued the ON signal.
  • Causes: • Fan defective • Foreign object interfering with operation of fan • Motor harness loose, disconnected, or broken • SIOB defective • SBU defective
  • Code: SC195
  • Description: Machine serial number error
    The number registered for the machine serial number does not match.
  • Causes: • Confirm the correct serial number of the machine in the specifications
  • Code: SC202
  • Description: Polygon motor error 1: ON timeout
    The polygon mirror motor does not reach the targeted operating speed: • Within 10 seconds after turning on. • Within 10 sec. after changing speed
  • Causes: • Harness to polygon motor driver board disconnected, defective • Polygon motor defective • Polygon motor driver board defective • Polygon motor defective.
  • Code: SC203
  • Description: Polygon motor error 2: OFF timeout
    The polygon mirror motor does leave the READY status within 10 seconds after the polygon motor switches off.
  • Causes: • Harness to polygon motor driver board disconnected, defective • Polygon motor defective • Polygon motor driver board defective • Polygon motor defective.
  • Code: SC204
  • Description: Polygon motor error 3: XSCRDY signal error
    The SCRDY_N signal goes HIGH (inactive) while the laser diode is firing.
  • Causes: • Harness to polygon motor driver board disconnected, defective • Polygon motor defective • Polygon motor driver board defective