PrintCopy.info service

Ricoh Aficio 3232C

Error Codes List page 2

  • Code: 195
  • Description: Serial number mismatch
    Serial number stored in the memory is not correct.
  • Causes: • NVRAM defective • BICU replaced without original NVRAM
  • Code: 199
  • Description: PSU fan error
    The PSU fan low signal is detected for 2 seconds when the PSU fan controller sends the high signal to the PSU fan.
  • Causes: • PSU fan defective • Disconnected or damaged harness
  • Code: 201
  • Description: Polygon motor error
    • The polygon motor starts operating or changes its speed. The lock signal is not detected within 5 seconds. • The polygon motor stops operating. The lock signal is still detected for 3 seconds. • The polygon motor is operating. The lock signal remains undetected for 0.5 seconds.
  • Causes: • Defective polygon motor • Defective harness
  • Code: 220
  • Description: 1st beam synchronization error
    A polygon motor lock is detected; the LD door is closed; and the LD remains on. The LD error (1st beam synchronization error) continues for 0.5 seconds.
  • Causes: • Disconnected synchronization detector board • Defective LD unit • Defective BICU
  • Code: 221
  • Description: 2nd beam synchronization error
    A polygon motor lock is detected; the LD door is closed; and the LD remains on. The LD error (2nd beam synchronization error) continues for 0.5 seconds.
  • Causes: • Disconnected synchronization detector board • Defective LD unit • Defective BICU
  • Code: 230
  • Description: FGATE on error
    A transfer belt mark is detected. No FGATE on signal is detected within 1 second.
  • Causes: • Defective BICU