PrintCopy.info service

Ricoh Aficio 1105

Error Codes List page 3

  • Code: SC302
  • Description: Charge corona output error 3
    The control PWM for the charge grid is too high.
  • Causes: • Charge P.P. defective • Poor charge corona unit connection
  • Code: SC303
  • Description: Charge corona output error 4
    The feedback voltage from the charge grid is too high.
  • Causes: • Charge P.P. defective • Poor charge corona unit connection
  • Code: SC305
  • Description: Charge corona wire cleaner error 1
    The charge corona wire cleaner does not return to its home position.
  • Causes: • Charge corona wire cleaner motor defective • Charge P.P. defective • IOB defective
  • Code: SC306
  • Description: Charge corona wire cleaner error 2
    The charge corona wire cleaner motor connector is not connected.
  • Causes: • The charge corona wire cleaner motor connector is not connected.
  • Code: SC310
  • Description: Potential sensor error 1
    When calibrating the drum potential sensor at the process control initial setting, the drum potential sensor output voltage is out of specification.
  • Causes: • Potential sensor defective • Poor connection between the potential sensor and the I/O board (IOB) • IOB defective • Poor connection between the drum unit and the I/O board (IOB) • Development power pack defective
  • Code: SC311
  • Description: Potential sensor error 2
    When calibrating the drum potential sensor at the process control initial setting, the rate of change of drum potential sensor output with voltage on the drum is out of specification.
  • Causes: • Potential sensor defective • Poor connection between the potential sensor and the I/O board (IOB) • IOB defective • Poor connection between the drum unit and the I/O board (IOB) • Development power pack defective