  • Code: 304
  • Description: Charge grid circuit open
    When high voltage goes to the corona grid, feedback voltage is more than the set value 9 times. This feedback voltage is used to update PWM for output control.
  • Causes: • Charge corona unit defective or disconnected
    • Charge corona harness defective
    • Charge corona power pack is defective.
  • Code: 305
  • Description: Charge corona wire cleaner error 1
    The charge cleaner pad does not arrive at the home position:
    • Motor locked within 4 s after switching on, or does not lock within 30 s.
    • Motor locked within 10 s after reversing, or does not lock within 30 s.
  • Causes: • Charge corona wire cleaner motor defective
    • Motor driver defective
  • Code: 306
  • Description: Charge corona wire cleaner error 2
    Charge coronal motor is disconnected. (The current at the charge corona motor is detected less than 83 mA.)
  • Causes: • Charge corona wire cleaner motor connector is defective, connected
  • Code: 310
  • Description: Potential sensor calibration error 1
    During drum potential sensor calibration, the drum potential sensor output voltage does not meet specification when test voltages (– 100V, –800V) are applied to the drum.
  • Causes: • Potential sensor defective
    • Potential sensor harness disconnected
    • Potential sensor connector defective or disconnected
    • IOB defective
    • OPC connector defective
    • Development power pack defecti
  • Code: 311
  • Description: Potential sensor calibration error 2
    During drum potential sensor calibration, the drum potential sensor output voltage does not meet specification when test voltages (– 100V, –800V) are applied to the drum.
  • Causes: • Potential sensor defective
    • Potential sensor harness disconnected
    • Potential sensor connector defective or disconnected
    • IOB defective
    • OPC connector defective
    • Development power pack defective
  • Code: 312
  • Description: Potential sensor calibration error 3
    During drum potential sensor calibration when adjusting the drum potential (VD), the drum potential sensor detects VD higher than VG (grid voltage). -or- When adjusting VD (drum surface potential of black areas after exposure), even after 5 adjustments of VG (charge corona grid potential), VD could not be set in the target range (– 800±10 + VL + 130V)
  • Causes: • Potential sensor defective
    • Potential sensor harness disconnected
    • Potential sensor connector defective or disconnected
    • IOB defective
    • OPC connector defective
    • Development power pack defective
    • Charge corona unit worn out, dirty