- Code: 901
- Description: SC901 Mechanical total count error
The IO board cannot receive the mechanical total count data.
- Causes: • Mechanical total counter defective
- Code: 951
- Description: F-gate error at write request
After the IPU receives an F-gate signal, it receives another F-gate signal.
- Causes: • Software defective • BICU defective
- Code: 953
- Description: Scanner setting error
The IPU does not respond with the scanner setting signal required to start scanning processing.
- Causes: • Software defective
- Code: 954
- Description: Printer setting error
The IPU does not respond with the settings that are required to start image processing by the printer.
- Causes: • Software defective
- Code: 955
- Description: Memory setting error
The IPU does not respond with the settings that are required to start image processing using the memory.
- Causes: • Software defective
- Code: 964
- Description: Printer ready error
The printer ready signal is not generated within 17 seconds after the IPU received the print start signal.
- Causes: • Software defective