  • Code: 192
  • Description: Automatic SBU adjustment error
    During the automatic SBU adjustment, the machine detects that the white level read from the white plate or paper is out of range.
  • Causes: • Exposure lamp defective • SBU auto adjustment was not done correctly • SBU defective • BiCU board defective • Exposure lamp stabilizer defective
  • Code: 194
  • Description: SBU White Level Detection Error
    The automatic SBU adjustment failed twenty times consecutively.
  • Causes: • Exposure lamp defective • Dirty white plate • Incorrect position or width of white plate scanning • BiCU board defective • SBU board defective
  • Code: 302
  • Description: Charge roller current leak
    A current leak signal for the charge roller is detected.
  • Causes: • Charge roller damaged • High voltage supply board defective • Poor connection of the PCU
  • Code: 320
  • Description: Polygonal mirror motor error
    The polygon mirror motor does not reach operating speed within 10 seconds after the motor ON signal is sent, or does not turn on within one of the 200 ms check intervals during operation.
  • Causes: • Polygon mirror motor defective • Poor connection between the polygonal mirror motor driver and the BiCU board • Damaged cable between BiCU/IOB and polygonal mirror motor driver • BiCU board defective
  • Code: 321
  • Description: No laser writing signal (F-GATE) error
    The laser writing signal (F-GATE) fails to turn Low after the laser crosses 5 mm on the drum surface from the laser writing start position.
  • Causes: • BiCU board defective • IMB board defective • The fax controller or printer controller has a poor connection • Fax controller or printer controller defective
  • Code: 322
  • Description: Laser synchronization error
    The main scan synchronization detector board cannot detect the laser synchronization signal for more than 5 consecutive 100 ms intervals.
  • Causes: • Poor connection between the LD unit and the BICU board • Damaged cable between BiCU and LD unit • LD unit out of position • LD unit defective • BiCU board defective