Description: Charge corona wire cleaner error 2
The charge corona wire cleaner motor connector is not connected.
Causes: • The charge corona wire cleaner motor connector is not connected.
Code: SC310
Description: Potential sensor error 1
When calibrating the drum potential sensor at the process control initial setting, the drum potential sensor output voltage is out of specification.
Causes: • Potential sensor defective • Poor connection between the potential sensor and the I/O board (IOB) • IOB defective • Poor connection between the drum unit and the I/O board (IOB) • Development power pack defective
Code: SC311
Description: Potential sensor error 2
When calibrating the drum potential sensor at the process control initial setting, the rate of change of drum potential sensor output with voltage on the drum is out of specification.
Causes: • Potential sensor defective • Poor connection between the potential sensor and the I/O board (IOB) • IOB defective • Poor connection between the drum unit and the I/O board (IOB) • Development power pack defective