PrintCopy.info service

Ricoh A265 Aficio 220 R-C1

Error Codes List page 3

  • Code: SC390
  • Description: TD sensor error 1
    The TD sensor outputs less than 0.5V or more than 4.0V 10 times consecutively during copying.
  • Causes: • TD sensor abnormal • Poor connection of the PCU
  • Code: SC391
  • Description: Development bias leak
    A development bias leak signal is detected.
  • Causes: • Poor connection of the PCU • High voltage supply board defective
  • Code: SC392
  • Description: TD sensor initial setting error
    TD sensor output voltage falls out of the adjustment range (2.0 +- 0.2 V) after the TD sensor initial setting has been finished.
  • Causes: • Someone forgot to remove the toner seal of the PCU • ID sensor defective • TD sensor abnormal • Drum does not turn • Development roller does not turn • Poor connection of the PCU
  • Code: SC401
  • Description: Transfer roller leak error 1
    A transfer roller current leak signal is detected. The current feedback signal for the transfer roller is not detected.
  • Causes: • High voltage supply board defective • Poor connection of the PCU • Transfer/separation unit set incorrectly • Transfer roller damaged
  • Code: SC402
  • Description: Transfer roller leak error 2
    A transfer roller current leak signal is detected. The current feedback signal for the transfer roller is not detected.
  • Causes: • High voltage supply board defective • Poor connection of the PCU • Transfer/separation unit set incorrectly • Transfer roller damaged
  • Code: SC411
  • Description: Separation bias leak error
    A separation bias leak signal is detected.
  • Causes: • High voltage supply board defective • Poor connection of the PCU • Discharge plate defective