  • Code: SC920
  • Description: MSU connection error
    The MSU set signal is not detected
  • Causes: • Poor connection between the BICU board and the MSU • BICU board defective • MSU defective
  • Code: SC921
  • Description: MSU hardware error
    The hardware of the MSU is defective
  • Causes: • MSU defective • BICU defective • Front door safety switch does not work properly
  • Code: SC980
  • Description: Program loading error
    The program cannot load properly.
  • Causes: • Poor connection between the BICU and the ROM board • BICU board defective • ROM board or the program defectiveM
  • Code: SC981
  • Description: NVRAM clear error
    The data stored in the NVRAM is not cleared properly when the Memory All Clear is performed.
  • Causes: • NVRAM defective
  • Code: SC990
  • Description: Communication error between BICU and IOCSS board
    The BiCU board cannot communicate with the IOCSS board properly.
  • Causes: • Poor connection between the BiCU board and the IOCSS board • BiCU board defective • IOCSS board defective