- Code: 30
- Display: Service call 030:Error
- Description: CU RAM Check Error
- Causes: Does error display reappear?
- Remedy: Power OFF/ON Replace ARC/SPY/SPA board.
- Code: 901, 902
- Display: Power off/on 901:Error 902:Error
- Description: Short or open in belt thermistor detected.
- Causes: Is belt thermistor cable setting proper? Does error reoccur?
- Remedy: Connect cable set properly again. Turn power ON again. Replace belt thermistor.
- Code: 903, 904
- Display: Power off/on 903:Error 904:Error
- Description: Abnormal temperature detected by belt thermistor (high-temp or low temp.)
- Causes: Is belt thermistor cable setting proper? Does error reoccur?
- Remedy: Connect cable set properly again. Turn power ON again. Replace belt thermistor and leave aside for 30 min. Then turn power ON again.
- Code: 905
- Display: Service call 905:Error
- Description: An open error of frame thermistor (defective thermistor or improper connection) detected.
- Causes: Does error reoccur?
- Remedy: Turn power ON again. Replace the fuser unit.
- Code: 906
- Display: Service call 906:Error
- Description: A short circuit error of frame thermistor (defective improper) detected.
- Causes: Does error reoccur?
- Remedy: Turn power ON again. Replace the fuser unit.
- Code: 907
- Display: Service call 907:Error
- Description: A high temperature error (over 150°C) of frame thermistor detected.
- Causes: Does error reoccur?
- Remedy: Turn power ON again. Replace the fuser unit.