PrintCopy.info service

OKI C130

Error Codes List page 1

  • Code: 0001
  • Description: Transport motor malfunction
    • The motor lock signal remains HIGH for a predetermined consecutive period of time while the transport motor remains energized.
    • The rack positioning sensor is in the blocked state when the rack motor remains deenergized.
    • The rack positioning sensor is not blocked a second time even after the lapse of a predetermined period of time after it has been blocked once while the rack motor remains energized.
  • Causes: Transport motor (M1) Printer control board (PRCB) DC power supply (DCPU)
  • Remedy: 1 Check the M1 connector for proper connection and correct as necessary. - - 2 Check M1 for proper drive coupling and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 M1 operation check. PRCB PJ8-1 to 6 C110: C-2 C130n: C-2 5 Change PRCB. - - 6 Change DCPU. - -
  • Code: 001B
  • Description: Rack rotation failure
    • The rack positioning sensor is unable to detect the deceleration control position after the lapse of a given period of time after the rack motor has started while the rack motor is turning.
    • The count value of the edge of ON signal of the rack positioning sensor during each developing positions are not a predetermined value while the rack motor is turning.
  • Causes: Rack motor (M2) Rack positioning sensor (PS5) Printer control board (PRCB)
  • Remedy: 1 Check the M2 connector for proper connection and correct as necessary. - - 2 Check M2 for proper drive coupling and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 PS5 sensor check. PRCB PJ5-11 (ON) C110: C-11 to 12 C130n: C-11 to 12 5 M2 operation check. PRCB PJ5-5 to 8 C110: C-12 C130n: C-12 6 Change PRCB. - -
  • Code: 004A
  • Description: Duplex unit cooling fan motor malfunction
  • Causes:
  • Remedy:
  • Code: 004C
  • Description: Ozone ventilation fan motor malfunction
    • The ozone ventilation fan motor does not rotate evenly even after the lapse of a given period of time while it is being started.
    • The motor lock signal remains HIGH for a given period of consecutive time while the ozone ventilation fan motor is being rotated.
  • Causes: Ozone ventilation fan motor (FM2) Printer control board (PRCB)
  • Remedy: 1 Check the FM2 connector for proper connection and correct as necessary. - - 2 Check the fan for possible overload and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 FM2 operation check. PRCB PJ16-1 (REM) PRCB PJ16-3 (LOCK) C110: C-4 C130n: C-4 5 Change FM2. - - 6 Change PRCB. - -
  • Code: 004E
  • Description: Power supply cooling fan motor malfunction
    • The fan motor lock signal remains HIGH for a predetermined consecutive period of time while the power supply cooling fan motor remains energized.
  • Causes: DC power supply fan motor (FM1) Printer control board (PRCB) DC power supply (DCPU)
  • Remedy: 1 Check the FM1 connector for proper connection and correct as necessary. - - 2 Check the fan for possible overload and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 FM1 operation check. HV CN2-1 (REM) HV CN2-3 (LOCK) C110: B-5 C130n: B-4 to 5 5 Change PRCB. - - 6 Change DCPU. - -
  • Code: 0092
  • Description: Transfer belt rotation failure
    • The belt positioning sensor does not detect the transfer belt position detection hole a second time even after the lapse of a predetermined period of time after it has detected one while the transfer belt is rotated.
  • Causes: Belt positioning sensor (PS6) Imaging cartridge Printer control board (PRCB)
  • Remedy: 1 Check the PRCB connector for proper connection and correct as necessary. - - 2 PS6 sensor check. - - 3 Change Imaging cartridge. - - 4 Change PRCB.
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?
Send message to us