  • Code: U2 00
  • Description: EEPROM read/write error (Controller). EEPROM write error
  • Causes: EEPROM trouble EEPROM is not initialized. Controller PWB EEPROM access circuit trouble
  • Remedy: Check that EEPROM is properly inserted. Save the counter/adjustment values with the DIAG simulation. Use DIAG (SIM16) to cancel U2 trouble. Replace the Controller PWB.
  • Code: U2 11
  • Description: Counter check sum error (Controller). Counter data area check sum error
  • Causes: EEPROM trouble Control circuit trouble by noise Controller PWB EEPROM access circuit trouble
  • Remedy: Check that EEPROM is properly inserted. Save the counter/adjustment values with the DIAG simulation. Use DIAG (SIM16) to cancel U2 trouble. Replace the Controller PWB.
  • Code: U2 12
  • Description: Adjustment value check sum error (Controller)
  • Causes: EEPROM trouble Control circuit trouble by noise Controller PWB EEPROM access circuit trouble
  • Remedy: Check that EEPROM is properly inserted. Save the counter/adjustment values with the DIAG simulation. Use DIAG (SIM16) to cancel U2 trouble. Replace the Controller PWB.
  • Code: U2 90
  • Description: PCU EEPROM write error
  • Causes: EEPROM trouble EEPROM is not initialized. PCU PWB EEPROM access circuit trouble
  • Remedy: Check that EEPROM is properly inserted. Save the counter/adjustment values with the DIAG simulation. Use DIAG (SIM16) to cancel U2 trouble. Replace the Controller PWB.
  • Code: U2 91
  • Description: PCU memory check sum error
  • Causes: EEPROM trouble EEPROM is not initialized. PCU PWB EEPROM access circuit trouble Uninitialized E2PROM installed.
  • Remedy: Check that EEPROM is properly inserted. Save the counter/adjustment values with the DIAG simulation. Use DIAG (SIM16) to cancel U2 trouble. Replace the Controller PWB.
  • Code: U6 00
  • Description: Desk/LCC communication error Communication cable test error after turning on the power or exiting DIAG.
  • Causes: Improper connection or disconnection of connector and harness Desk control PWB trouble Control PWB (PCU) trouble Malfunction by noise
  • Remedy: Canceled by turning OFF/ON the power. Check connection of the harness and connector in the communication line.