PrintCopy.info service

Mutoh ValueJet 1617H

Error Codes List page 6

  • Code: E094
  • Display: E094Err PF Drv Temp
  • Description: This indicates that the PF motor is overloaded, with fever.
  • Remedy: 1. Is the weight of the media used within the recommended weight? Explain the user about the recommended media weight. 2. Is there paper jam around Grid roller? Remove paper jam, check if Media holder and Print head are damaged, and check if the same error occurs. 3. Doesn't PF motor get hot? Replace PF motor. 4. MAIN board may be damaged. Replace MAIN board.
  • Code: E095
  • Display: E095Err PFDrv Err
  • Description: This indicates that the PF motor is overloaded with fever or decreased supply voltage (24V).
  • Remedy: 1. Is the weight of the media used within the recommended weight? Explain the user about the recommended media weight. 2. Is there paper jam around Grid roller? Remove paper jam, check if Media holder and Print head are damaged, and check if the same error occurs. 3. Doesn't PF motor get hot? Replace PF motor. 4. MAIN board may be damaged. Replace it. 5. Power board may be damaged. Replace it.
  • Code: E097
  • Display: E097 Err NVRAM.
  • Description: An anomaly is detected in NVRAM.
  • Remedy: Replace MAIN board
  • Code: E124
  • Display: E124 Err PG Origin
  • Description: This indicates that PG origin is not detected.
  • Remedy: 1. Check the connection of PG origin sensor, PG motor connector and CR FFC. Make sure to connect it surely. 2. Is the screw of coupling installed on PG motor loose? Make sure to tighten it surely. 3. Is the coupling skewed? Make sure to tighten it surely. 4. Is the screw on Worm drive loose? Make sure to tighten it surely. 5. Is the direction of worm wheel appropriate? Make sure to mount it surely. 6. PG origin sensor may be damaged. Replace it. 7. CR board may be damage. Replace it. 8. CR_FFC may be damaged. Replace it. 9. PG motor may be damaged. Replace it. 10. MAIN board may be damaged. Replace it.
  • Code: E125
  • Display: E125 Err P Height Sns
  • Description: An anomaly is detected in Media thickness detection sensor
  • Remedy: 1. Check if Solenoid at media detection area is operating properly when detecting the media thickness. If it is malfunctioning, replace Media thickness detection solenoid. 2. Check the connection of Media thickness detection solenoid relay connector. Make sure to connect it surely. 3. Check the connection of Media thickness detection sensor connector. Make sure to connect it surely. 4. Check the connection of CR_FFC. Make sure to connect it surely. 5. Media thickness detection sensor may be malfunctioning. • If PG value was changed manually and PG has not been adjusted after changing Head, perform PG adjustment. • Replace Media thickness detection sensor. 6. CR_FFC may be damaged. Replace it. 7. CR board may be damaged. Replace it. 8. MAIN board may be damaged. Replace it.
  • Code: E126
  • Display: E126 Err PG Motor
  • Description: An anomaly is detected in PG motor driver.
  • Remedy: 1. Check the connection of CR FFC. Make sure to connect it surely. 2. CR FFC may be damaged. Replace it. 3. CR board may be damaged. Replace it. 4. MAIN board may be damaged. Replace it.
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?
Send message to us