PrintCopy.info service

Mimaki UJF6042

Error Codes List page 2

  • Code: 108
  • Display: ERROR 108 HD CONNECT[12345678]
  • Description: Head connection error (Head connection can not be confirmed)
  • Remedy: 1. Check the setting of loading number of the head in the parameter. (System parameter No.41 HEAD NO=3) 2. Disconnect and connect the FFC located between the Slider PCB and the SL-Relay PCB. 3. Check connection between the Slider PCB from the Print Head 4. Replace the Slider PCB with a new one. 5. Replace the Print Head with a new one.
  • Code: 108
  • Display: ERROR 108 HD THERMIS[12345678]
  • Description: Head thermistor (Head temperature can not be measured)
  • Remedy: 1. Check the setting of loading number of the head in the parameter. (System parameter No.41 HEAD NO=3) 2. Disconnect and connect the FFC located between the Slider PCB and the SL-Relay PCB. 3. Check connection between the Slider PCB from the Print Head 4. Replace the Slider PCB with a new one. 5. Replace the Print Head with a new one.
  • Code: 10a
  • Display: SYSTEM HALT (*) 10a : HDC INIT
  • Description: Initialization error of the Slider PCB (FPGA)
  • Remedy: 1. Check the connections between the SL-Relay PCB and the Slider PCB, and then disconnect and connect the FFCs or the like. 2. Check the connections between the SL-Relay PCB and the Main PCB, and then disconnect and connect the FFCs or the like. 3. Replace the FFCs and the cabeles of the above routes. 4. Replace the Slider PCB with a new one. 5. Replace the SL-Relay PCB with a new one. 6. Replace the Main PCB with a new one.
  • Code: 10b
  • Display: SYSTEM HALT (*) 10b : PCB SLRY-F3
  • Description: Initialization error of the SL-Relay PCB (FPGA)
  • Remedy: 1. Check the connections between the SL-Relay PCB and the Main PCB, and then disconnect and connect the FFCs or the like. 2. Replace the FFCs of the above routes. 3. Replace the SL-Relay PCB with a new one. 4. Replace the Main PCB with a new one.
  • Code: 10e
  • Display: SYSTEM HALT (*) 10e :FROM CLEAR
  • Description: F-ROM CLEAR error (F-ROM clear unable) F-ROM is not clearable on Parameter writing, FW down loading and Log clearing. (fls_secclr)
  • Remedy: 1. Execute the memory check (F-ROM) of [#TEST]. 2. Upload the parameter and initialize all parameters with [#PARAMETER]. 3. Replace the Main PCB with a new one.
  • Code: 10f
  • Display: SYSTEM HALT (*) 10f : FROM WRITE
  • Description: FROM WRITE error (F-ROM writing unable) F-ROM is not clearable on Parameter writing, FW down loading and Log clearing. (fls_secclr)
  • Remedy: 1. Execute the memory check (F-ROM) of [#TEST]. 2. Upload the parameter and initialize all parameters with [#PARAMETER]. 3. Replace the Main PCB with a new one.