Remedy: 1. Check the connections between the Keyboard PCB and the Main PCB and then disconnect and connect the FFCs. 2. Replace the FFCs of the above routes. 3. Replace the Keyboard PCB with a new one. 4. Replace the Main PCB with a new one. (Refer to 3.3.1
Code: 114
Display: SYSTEM HALT (*) 114 : PCB PUMP
Description: No Pump III PCB
Remedy: 1.Check the connections between the Pump PCB and the Main PCB, and then disconnect and connect the FFCs . 2. Replace the FFCs of the above routes. 3. Replace the Pump III PCB with a new one. 4. Replace the Main PCB with a new one. 5. Replace the SL-Relay PCB with a new one.
Code: 115
Display: SYSTEM HALT (*) 115 : PCB MAIN-F1
Description: Main PCB fuse (F1) disconnected.
Remedy: Replace the Main PCB with a new one. Before Main PCB replace, do the following checks. 1. Check the connections between the SL-Relay PCB and the Main PCB, and then disconnect and connect the FFCs or the like. 2. Check short between 1 pin and 12 pin, and between 3 pin and 12 pin of CN6 of the SL-Relay PCB. (If shorted out, replace also the SL-Relay PCB.) 3. Check the connections between the SL-Relay PCB and the Slider PCB and then disconnect and connect the FFCs or the like. 4. Check short between 1 pin and 16 pin, and between 3 pin and 16 pin of CN1 of the Slider PCB. (If shorted out, replace also the Slider PCB.)
Code: 116
Display: SYSTEM HALT (*) 116 : PCB MAIN-F2
Description: Main PCB fuse (F2) disconnected.
Remedy: Replace the Main PCB with a new one. Before Main PCB replace, do the following checks. 1. Check the connections between the SL-Relay PCB and the Main PCB, and then disconnect and connect the FFCs or the like. 2. Check short between 1 pin and 12 pin, and between 3 pin and 12 pin of CN6 of the SL-Relay PCB. (If shorted out, replace also the SL-Relay PCB.) 3. Check the connections between the SL-Relay PCB and the Slider PCB and then disconnect and connect the FFCs or the like. 4. Check short between 1 pin and 16 pin, and between 3 pin and 16 pin of CN1 of the Slider PCB. (If shorted out, replace also the Slider PCB.)
Code: 117
Display: SYSTEM HALT (*) 117 : PCB MAIN-F3
Description: Main PCB fuse (F3) disconnected.
Remedy: Replace the Main PCB with a new one. Before Main PCB replace, do the following checks. 1. Check the connections between the SL-Relay PCB and the Main PCB, and then disconnect and connect the FFCs or the like. 2. Check short between 1 pin and 12 pin, and between 3 pin and 12 pin of CN6 of the SL-Relay PCB. (If shorted out, replace also the SL-Relay PCB.) 3. Check the connections between the SL-Relay PCB and the Slider PCB and then disconnect and connect the FFCs or the like. 4. Check short between 1 pin and 16 pin, and between 3 pin and 16 pin of CN1 of the Slider PCB. (If shorted out, replace also the Slider PCB.)
Code: 11b
Display: SYSTEM HALT (*) 11b : SLDR FPC L
Description: Connection check error of FPC cable between SL-Relay PCB and Slider PCB
Remedy: 1. Check whether FPC cable connection connector of the Slider PCB (CN2, 4, 6) and the SL-Relay PCB (CN3, 7, 8) is proper. 2. Disconnect and connect the FFC and Twist pair Cable located between the Slider PCB and the SL-Relay PCB. 3. Disconnect and connect the FFC and Twist pair Cable located between the Main PCB and the SL-Relay PCB. 4. Replace the FFC(or Twist pair Cable) located between the Slider PCB and the SL-Relay PCB. 5. Replace the FFC(or Twist pair Cable) located between the Main PCB and the SL-Relay PCB. 6. Replace the Slider PCB with a new one. 7. Replace the SL-Relay PCB with a new one. 8. Replace the Main PCB with a new one.