PrintCopy.info service

Mimaki JFX500-2131

Error Codes List page 3

  • Code: 120
  • Display: SYSTEM HALT (*) 120 : LCD THERM.
  • Description: LCD thermistor IC RW error
  • Remedy: 1. Check the connections between the keyboard PCB and the main PCB, and then disconnect and connect the FFCs. 2. Replace the FFCs and the cables of the above routes. 3. Replace the keyboard PCB with a new one. 4. Replace the main PCB with a new one. 5. Replace the DC power supply (5V) with a new one.
  • Code: 122
  • Display: SYSTEM HALT (*) 122 : PRAM NONE
  • Description: No PRAM
  • Remedy: 1. Update F/W. 2. Replace the PRAM PCB with a new one. 3.Replace the main PCB with a new one.
  • Code: 122
  • Display: ERROR 122 CHECK:SDRAM
  • Description: PRAM size is not sufficient at FW upgrading (fw_updmsg). 1. Update F/W. 2. Replace the main PCB with a new one. 3. Replace the PRAM PCB with a new one.
  • Remedy: 1. Update F/W. 2. Replace the main PCB with a new one. 3. Replace the PRAM PCB with a new one.
  • Code: 123
  • Display: SYSTEM HALT (*) 123 : PRAM DATA
  • Description: PRAM data error
  • Remedy: 1. Update F/W. 2. Replace the PRAM PCB with a new one. 3.Replace the main PCB with a new one.
  • Code: 124
  • Display: SYSTEM HALT (*) 124 : PRAM ADDR
  • Description: PRAM address error
  • Remedy: 1. Update F/W. 2. Replace the PRAM PCB with a new one. 3.Replace the main PCB with a new one.
  • Code: 125
  • Display: SYSTEM HALT (*) 125 : EEPROM READ
  • Description: EEPROM read trouble CIO Register (EER:Address 74) bit6
  • Remedy: 1. Update F/W. 2. Upload the parameter and initialize parameter with #PARAMETER. 3. Check the connection state between main PCB - central-IO PCB. 4. Replace the main PCB with a new one. 5. Replace the central-IO PCB with a new one.