Mimaki JFX1631

Error Codes List page 25

  • Code: 80a
  • Display: SYSTEM HALT (*) 80a : FW/Y RANGE
  • Description: FW error (Y movable range error)
  • Remedy: 1. Update F/W. 2. Check and clear the parameter. 3. Disconnect and connect the FFC located between the FFC Junction PCB and the SL-Relay PCB. Also, confirm that insulating sheets have been inserted between six FFCs. 4. Disconnect and connect the FFC located between the SL-Relay PCB and the Slider PCB. Also, confirm that insulating sheets have been inserted between six FFCs. 5. Replace the FFC located between the FFC Junction PCB and the SL-Relay PCB. 6. Replace the FFC located between the SL-Relay PCB and the Slider PCB. 7. Replace the Main PCB with a new one.
  • Code: 80b
  • Display: SYSTEM HALT (*) 80b : FW/ctrltsk
  • Description: FW error (Motor control task error)
  • Remedy: 1. Update F/W. 2. Check and clear the parameter. 3. Disconnect and connect the FFC located between the FFC Junction PCB and the SL-Relay PCB. Also, confirm that insulating sheets have been inserted between six FFCs. 4. Disconnect and connect the FFC located between the SL-Relay PCB and the Slider PCB. Also, confirm that insulating sheets have been inserted between six FFCs. 5. Replace the FFC located between the FFC Junction PCB and the SL-Relay PCB. 6. Replace the FFC located between the SL-Relay PCB and the Slider PCB. 7. Replace the Main PCB with a new one.
  • Code: 80c
  • Display: SYSTEM HALT (*) 80c : FW/PUMP W
  • Description: FW error (Suction Pump stop waiting time over at capping)
  • Remedy: 1. Update F/W. 2. Check and clear the parameter. 3. Disconnect and connect the FFC located between the FFC Junction PCB and the SL-Relay PCB. Also, confirm that insulating sheets have been inserted between six FFCs. 4. Disconnect and connect the FFC located between the SL-Relay PCB and the Slider PCB. Also, confirm that insulating sheets have been inserted between six FFCs. 5. Replace the FFC located between the FFC Junction PCB and the SL-Relay PCB. 6. Replace the FFC located between the SL-Relay PCB and the Slider PCB. 7. Replace the Main PCB with a new one.
  • Code: 80d
  • Display: SYSTEM HALT (*) 80d : FW/SERVO IT
  • Description: FW error (Servo interruption error)
  • Remedy: 1. Update F/W. 2. Check and clear the parameter. 3. Disconnect and connect the FFC located between the FFC Junction PCB and the SL-Relay PCB. Also, confirm that insulating sheets have been inserted between six FFCs. 4. Disconnect and connect the FFC located between the SL-Relay PCB and the Slider PCB. Also, confirm that insulating sheets have been inserted between six FFCs. 5. Replace the FFC located between the FFC Junction PCB and the SL-Relay PCB. 6. Replace the FFC located between the SL-Relay PCB and the Slider PCB. 7. Replace the Main PCB with a new one.
  • Code: 80e
  • Display: SYSTEM HALT (*) 80e : FW/FROM prm
  • Description: FW error (FROM PARAM error (F/W BUG))
  • Remedy: 1. Update F/W. 2. Check and clear the parameter. 3. Disconnect and connect the FFC located between the FFC Junction PCB and the SL-Relay PCB. Also, confirm that insulating sheets have been inserted between six FFCs. 4. Disconnect and connect the FFC located between the SL-Relay PCB and the Slider PCB. Also, confirm that insulating sheets have been inserted between six FFCs. 5. Replace the FFC located between the FFC Junction PCB and the SL-Relay PCB. 6. Replace the FFC located between the SL-Relay PCB and the Slider PCB. 7. Replace the Main PCB with a new one.
  • Code: 80f
  • Display: SYSTEM HALT (*) 80f : FW/SIO vch
  • Description: FW error (Virtual serial CH setting error)
  • Remedy: 1. Update F/W. 2. Check and clear the parameter. 3. Disconnect and connect the FFC located between the FFC Junction PCB and the SL-Relay PCB. Also, confirm that insulating sheets have been inserted between six FFCs. 4. Disconnect and connect the FFC located between the SL-Relay PCB and the Slider PCB. Also, confirm that insulating sheets have been inserted between six FFCs. 5. Replace the FFC located between the FFC Junction PCB and the SL-Relay PCB. 6. Replace the FFC located between the SL-Relay PCB and the Slider PCB. 7. Replace the Main PCB with a new one.