  • Code: 10f
  • Display: SYSTEM HALT (*) 10f : FROM WRITE
  • Description: FROM WRITE error (F-ROM writing unable) F-ROM is not clearable on Parameter writing, FW down loading and Log clearing. (fls_secclr)
  • Remedy: 1. Execute the memory check (F-ROM) of [#TEST]. 2. Upload the parameter and initialize all parameters with [#PARAMETER]. 3. Replace the Main PCB with a new one.
  • Code: 110
  • Display: SYSTEM HALT (*) 110 : PCB KEY
  • Description: No keyboard PCB The ID of Keyboard PCB is not readable. For JFX, 3 PCBs of the keyboard PCB are mounted. • Keyboard PCB Assy. 1: Front operation unit • Keyboard PCB Assy. 2: Maintenance operation unit • Keyboard PCB Assy. 3: X-drive unit
  • Remedy: 1. Check the connections between the Keyboard PCB and the Main PCB (X-axis Control PCB), and then disconnect and connect the FFCs. 2. Check if the Cover Sensor Short Assy. is connected. 3. Confirm that there is neither damage nor disconnection on the FFCs of the above routes. 4. Replace the FFCs of the above routes. 5. Replace the Keyboard PCB with a new one. 6. Replace the Main PCB or the X-axis Control PCB with a new one.
  • Code: 112
  • Display: SYSTEM HALT (*) 112 : PCB CARTRIG
  • Description: No cartridge PCB The ID of Cartridge PCB is not readable.s
  • Remedy: 1. Check the connections between the Cartridge PCB, the Carrier IO PCB and the Main PCB, and then disconnect and connect the FFCs or the like. 2. Check if the Short Assy. of each PCB is connected. 3. Make sure that there is neither damaged nor disconnected on the FFCs or the like of the above routes. 4. Replace the FFCs or the like of the above routes. 5. Replace the Cartridge PCB with a new one. 6. Replace the Carrier IO PCB with a new one. 7. Replace the Main PCB with a new one.
  • Code: 114
  • Display: SYSTEM HALT (*) 114 : PCB PUMP
  • Description: No pump PCB The ID of Pump PCB is not readable.
  • Remedy: 1. Check the connections between the Pump PCB, the Carrier IO PCB and the Main PCB, and then disconnect and connect the FFCs or the like. 2. Check if the Short Assy. of each PCB is connected. 3. Make sure that there is neither damaged nor disconnected on the FFCs or the like of the above routes. 4. Replace the FFCs or the like of the above routes. 5. Replace the Pump PCB with a new one. 6. Replace the Carrier IO PCB with a new one. 7. Replace the Main PCB with a new one.
  • Code: 115
  • Display: SYSTEM HALT (*) 115 : PCB MAIN-F1
  • Description: Main PCB F1 fuse disconnected. On Slider PCB initializing (hardchk) of Initializing operation, NG in case of +35V power supply authorized state.
  • Remedy: 1. Replace the Main PCB with a new one. 2. Replace the SL-Relay PCB with a new one.
  • Code: 116
  • Display: SYSTEM HALT (*) 116 : PCB MAIN-F2
  • Description: Main PCB F2 fuse disconnected. On IO PCB fuse checking (hardchk) of Initializing operation, Main PCB F1 fuse disconnected, in case of SIOC_IO1.
  • Remedy: 1. Replace the Main PCB with a new one. 2. Replace the Carrier IO PCB with a new one.