PrintCopy.info service

Mimaki JF1610

Error Codes List page 2

  • Code: 10E
  • Display: F-ROM CLEAR
  • Description: F-ROM CLEAR error (F-ROM clear unable) F-ROM clear is disabled in parameter writing, FW downloading or log clearing (fls_secclr)
  • Remedy: 1. Execute the memory check (F-ROM) of #TEST. 2. Upload the parameter and initialize all parameters with #PARAMETER. 3. Replace the Main PCB with a new one.
  • Code: 10F
  • Display: F-ROM WRITE
  • Description: FROM WRITE error (F-ROM writing unable) F-ROM cannot be cleared in parameter writing, FW downloading or log clearing. (fls_seccclr)
  • Remedy: 1. Execute the memory check (F-ROM) of #TEST. 2. Upload the parameter and initialize all parameters with #PARAMETER. 3. Replace the main PCB with a new one.
  • Code: 110
  • Display: PCB KEY
  • Description: The keyboard PCB is not available. The ID of Keyboard PCB is not readable.
  • Remedy: 1. Check the connections between the keyboard PCB, the FPC junction PCB and the main PCB, and then disconnect and connect the FPCs. 2. Check if the cover sensor short assy is connected. 3. Confirm that there is neither damage nor disconnection on the FPCs of the above routes. 4. Replace the FPCs of the above routes. 5. Replace the Keyboard PCB with a new one. 6. Replace the FPC junction PCB with a new one. 7. Replace the Main PCB with a new one.
  • Code: 112
  • Display: PCB CARTRIG
  • Description: The cartridge PCB is not available The ID of cartridge PCB is not readable.
  • Remedy: 1. Check the connections between the cartridge PCB, the station PCB, the slider junction PCB, the FPC junction PCB and the main PCB, and then disconnect and connect the FPCs. 2. Check if the short assy of each PCB is connected. 3. Confirm that there is neither damage nor disconnection on the FPCs of the above routes. 4. Replace the FPCs of the above routes. 5. Replace the Cartridge PCB with a new one. 6. Replace the Station PCB with a new one. 7. Replace the Slider junction PCB with a new one. 8. Replace the FPC junction PCB with a new one. 9. Replace the Main PCB with a new one.
  • Code: 114
  • Display: PCB PUMP
  • Description: The pump PCB is not available The ID of pump PCB is not readable.
  • Remedy: 1. Check the connections between the pump PCB, the station PCB, the slider junction PCB, the FPC junction PCB and the main PCB, and then disconnect and connect the FPCs. 2. Check if the short assy of each PCB is connected. 3. Confirm that there is neither damage nor disconnection on the FPCs of the above routes. 4. Replace the FPCs of the above routes. 5. Replace the Pump PCB with a new one. 6. Replace the Station PCB with a new one. 7. Replace the Slider junction PCB with a new one. 8. Replace the FPC junction PCB with a new one. 9. Replace the Main PCB with a new one.
  • Code: 115
  • Display: PCB MAIN-F1
  • Description: Main PCB F1 fuse brown out (Fuse blow out of control PCB) “NG” in the case of the condition allowable for supplying +35V in initializing (hardchk) the slider junction PCB in the initializing process.
  • Remedy: 1. Replace the Main PCB with a new one. 2. Replace the FPC junction PCB with a new one. 3. Replace the Slider junction PCB with a new one.