  • Code: 04
  • Display: ERR 04 FLASH ROM
  • Description: Partial damage to saved parameters (The above phenomenon occurs, and then is repeated frequently even after recovered.)
  • Remedy: 1. Defective flash ROM Replace the flash ROM or Main PCB.
  • Code: 06
  • Display: ERR 06 BUFFER
  • Description: Defective SD-RAM Error was detected by read/write check of the received data storage area of the SDRAM on the Main PCB.
  • Remedy: 1. Execute Memory Check ([#TEST] -> [ROM/RAM CHECK]) 2. Update FW 3. Check/clear Parameters. 4. Replace the Main PCB.
  • Code: 08
  • Display: ERR 08 POWER
  • Description: Defective power supply or Main PCB (Motor control gate array shut down.) Damaged power supply or damaged Main PCB.
  • Remedy: 1. Replace the Power supply PCB. 2. Replace the Main PCB.
  • Code: 10
  • Display: ERR 10 COMMAND
  • Description: Received command was not recognized (Communication condition setting error in RS-232C connection)
  • Remedy: 1. Check Communication conditions of Host PC and set the plotter setting to the host PC. 2. Check Communication conditions by using Line analyzer if available.
  • Code: 10
  • Display: ERR 10 COMMAND
  • Description: Received command was not recognized (Command type setting error)
  • Remedy: 1. Check the output command on the application on the host computer or the plotter driver and select the plotter command type that is supported by the host computer. If both MGL_Ic1 and MGL_IIc are selectable, choose MGL_IIc with which the mark detect function is available. 2. If the command type is unknown, receive the command in AUTO to identify the command type. 3. If the command type is not recognized automatically in AUTO, identify the command type with the data monitor or the dump function.
  • Code: 10
  • Display: ERR 10 COMMAND
  • Description: Received command was not recognized (The application or the plotter driver does not support the CG-SRII command.)
  • Remedy: 1. Install a Mimaki plotter driver that is compatible with the application. 2. If the application has an output model selection function, select CG-SRII or any other Mimaki model (FX, EX, LX, ST, etc) and check. 3. Consult the application provider if a more recent version or a substitutable application (HP-GL or graphic command compatible) is available.