- Code: nc12
- Display: ** COPY XXXX **
- Description: Cutting according to multiple sheet cutting data is in progress.
- Remedy: This is not an error, so no action is necessary.
- Code: nc13
- Display: ** COPY **
- Description: "SINGLE COPY" execution is in progress.
- Remedy: This is not an error, so no action is needed.
- Code: nc14
- Display: *DIVISION* xx s
- Description: The machine is waiting for data from the host computer after executing the "DIVISION" function.
- Remedy: XXs: After the count is 0s, frame and mark will be cut and the machine will be in local mode.
- Code: nc15
- Display: RSl CSx DRx ERx
- Description: "RS-232C" is selected in "REMOTE DISP" function.
- Remedy: The signal Jines of the RS-232C are indicating.
- Code: nc16
- Display: RSl CSx DRx ERx CDx
- Description: "RS-232C" is selected in "REMOTE DISP" function and "LOOP BACK" test is being executed.
- Remedy: The signal lines of the RS-232C are indicating.
- Code: nc17
- Display: *TRANS.* XXXXKB
- Description: The data is being transmitted to the RS-232C port by "BUFFER DUMP" function.
- Remedy: The remaining data size is indicating.